Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable

  Windmill Cables

NYY 0.6/1kV Power Cable

NYY 0.6/1kV Power Cable

Application

These cables are designed for power lines of fixed routing in wind tower installation, also used as energy supply cables installed in underground, water, cable ducts, power stations, outdoors, indoors, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not expected.

Standards

IEC 60502
DIN VDE 0276 part 603

Construction

Conductor: Stranded copper conductor according to IEC60228/VDE 0295.
Insulation: PVC.
Filling: Filling compound over the core assembly.
Sheath: PVC.

Technical Data

Rated Voltage Uo/U (Um)

0.6/1kV

Operating Temperatures

flexing: -5℃~+50℃; fixed: -40℃~+70℃

Minimum Bending Radius

Single Core: 15×OD; Multicore:12×OD

Maximum Permissible Tensile Load

50N/mm²

Short-circuit Temperature

160℃

Flame Retardant

IEC 60332-1/VDE 0482-332-1-2

Silicone Free

Yes

Dimensions and Weight

NYY-J

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

1×25 rm

13

380

1×35 rm

14

447

1×50 rm

15

650

1×70 rm

17

864

3×1.5 re

12

223

4×1.5 re

13

256

5×1.5 re

14

293

7×1.5 re

15

360

10×1.5 re

18

520

12×1.5 re

19

560

14×1.5 re

20

620

16×1.5 re

21

680

19×1.5 re

22

760

24×1.5 re

24

900

30×1.5 re

26

1100

3×2.5 re

13

272

4×2.5 re

14

316

5×2.5 re

15

323

7×2.5 re

16

450

10×2.5 re

20

630

12×2.5 re

20

680

14×2.5 re

21

790

19×2.5 re

23

990

24×2.5 re

26

1300

30×2.5 re

28

1400

3×4 re

15

373

4×4 re

16

439

5×4 re

17

510

3×6 re

16

466

4×6 re

17

547

5×6 re

19

640

3×10 re

18

629

4×10 re

19

743

5×10 re

21

899

3×16 re

20

850

4×16 re

22

1039

5×16 re

23

1240

3×25 rm/16 re

25

1595

4×25 rm

27

1620

3×35 sm/16 re

27

1718

4×35 sm

27

1916

3×50 sm/25 sm

31

2383

4×50 sm

31

2639

3×70 sm/35 sm

33

3196

4×70 sm

35

3576

3×95 sm/50 sm

38

4271

4×95 sm

40

4746

3×120 sm/70 sm

41

5281

4×120 sm

43

5813

3×150 sm/70 sm

46

6408

4×150 sm

48

7263

3×185 sm/95 sm

50

7909

4×185 sm

53

8905

3×240 sm/120 sm

57

10162

4×240 sm

60

11430

NYY-O

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

1×10 re

10

176

1×16 re

11

239

1×25 re

13

380

1×35 re

14

447

1×50 rm

15

650

1×70 rm

17

864

1×95 rm

19

1132

1×120 rm

21

1405

1×150 rm

22

1710

1×185 rm

24

2086

1×240 rm

27

2669

1×300 rm

30

3305

1×500 rm

39

5400

2×1.5 re

11

210

2×2.5 re

12

250

4×2.5 re

14

316

2×4 re

14

360

4×4 re

16

439

2×6 re

15

400

4×6 re

17

547

2×10 re

17

500

4×10 re

19

743

4×16 re

22

1039

4×25 rm

27

1620

4×35 sm

27

1916

4×50 sm

31

2639

4×70 sm

35

3576

4×95 sm

40

4746

re: round conducter, single wire
rm: round conducter, multi wire
sm: sectional conductor