    Fire resistant cables VS Flame retardant cables

    An important distinction exists between fire resistant cables and flame retardant cables, even though both of them are subjected to various fire performance tests in order to earn their respective classification. In brief, flame retardant cables are designed to resist the spread of fire into a new area. Fire resistant or fire rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions. 

    Our fire performance cables are usually manufactured according to the standards as follows:

    Fire resistant and flame retardant standards:

    BS7629-1, BS8592, BS EN 50200 PH30 / PH60 / PH120, BS7846 and BS6387 CWZ,BS8491,BS8434-2, IEC 60331-21, IEC 60331-23, IEC 60331-25, IEC 60331-1, IEC 60331-2, IEC 60331-3, IEC 60332-1-2, IEC 60332-3-22, IEC 60332-3-23, IEC 60332-3-24, BS EN 60332-3-22, BS EN 60332-3-23, BS EN 60332-3-24

    Fire resistant standards:

    BS 7629-1 Electric cables – Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Part 1: Multicore cables
    BS 7846 Electric cables – Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire – Specification
    BS 8592 Electric cables – Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire – Specification
    BS EN 50200 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
    BS 6387 Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions
    BS8434-2 Methods of test for assessment of the fire integrity of electric cables - Part 2: Test for unprotected small cables for use in emergency circuits - BS EN 50200 with a 930 degree C flame and with water spray
    BS 8491 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems
    IEC 60331-21 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part 21: Procedures and Requirements - Cables of Rated Voltage up to and Including 0,6/1,0 kV
    IEC 60331-23 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part 23: Procedures and Requirements - Electric Data Cables
    IEC 60331-25 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part 25: Procedures and Requirements - Optical Fibre Cables
    IEC 60331-1 Tests for electric cables under fire conditions – Circuit integrity – Part 1: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
    IEC 60331-2 Tests for electric cables under fire conditions – Circuit integrity – Part 2: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20mm
    IEC 60331-3 Tests for electric cables under fire conditions – Circuit integrity – Part 3: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure

    Flame retardant standards:

    IEC 60332-1-2 Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
    IEC 60332-3-22 Test for vertical flame spread of vertical mounted bunched wires or cables - Category A
    IEC 60332-3-23 Test for vertical flame spread of vertical mounted bunched wires or cables - Category B
    IEC 60332-3-24 Test for vertical flame spread of vertical mounted bunched wires or cables - Category C