Windmill Cables | |||
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable |
Windmill Cables
S-3GSHCOEU 0.6/1 kV & UL 1000V 90CApplication
These cables are designed for use at medium mechanical stresses in wind turbines.
Standards
UL 758
DIN VDE 0250
Construction
Conductor: Stranded bare copper, class 5 according to IEC 60228/DIN EN 60228.
Insulation: Rubber compound.
Screen: Tinned copper wires. Mixed braid of tinned copper wires and polyester yarn can be offered
upon request.
Sheath: CPE.
Technical Data
Rated Voltage Uo/U (Um) |
600/1000V (DIN VDE 0250)/ 1000V (AWM 758) |
Operating Temperatures |
-40℃~+90℃ |
Maximum Permissible Tensile Load |
15 N/mm² |
Minimum Bending Radius |
flexing: 10×OD; fixed: 6×OD |
Short-circuit Temperature |
250℃ |
Flame Retardant |
IEC 60332-1 |
Oil Resistant |
Yes |
Ozone Resistant |
Yes |
UV Resistant |
Yes |
Dimensions and Weight
Construction |
Nominal Overall Diameter |
Nominal Weight |
No. of cores×mm² |
mm |
kg/km |
1×95 |
23.0 |
1120 |
1×120 |
26.0 |
1607 |
1×185 |
30.5 |
2341 |
1×240 |
34.0 |
2953 |