Application
These flexible and robust cables are designed for industrial use, suitable for fixed and normal flexible installations.
Standards
Construction
Core Type |
Tight buffer. |
Strain Relief |
Aramid yarns. |
Break-out Unit Sheath |
PVC. |
Outer Sheath |
PVC. |
Technical Data
Operating Temperatures |
-40℃~+80℃ |
Minimum Bending Radius |
During Installation: 60mm; Installation: 45mm |
Torsion Application |
180°/m |
Flame Retardant |
IEC 60332-1/IEC 60332-3/UL 1685 FT1+FT4 |
Oil Resistant |
Yes |
Ozone Resistant |
Yes |
UV Resistant |
Yes |
Dimensions and Weight
CONSTRUCTION |
FIBRE TYPE |
NOMINAL OVERALL DIAMETER |
NOMINAL WEIGHT |
NO. OF FIBRES |
|
MM |
KG/KM |
2 |
HCS 200/230 |
7.5 |
68 |