Quick Contact
The drop wires are designed for use in extending telephone circuits to subscriber premises by means of an aerial drop from distribution wire or cables. The shape may be in oval/dumbbell shape to aid in separation of conductors.
• RUS (REA) PE-7
• ASTM B227, B452 & B1
Construction
Two conductors made of 0.9/1.0/1.023mm copper covered steel wires serve dually as conductor and strength members
Bonding of the insulation to the conductors is made to assure the full conductor strength is transferred to the wire support clamps
Conductors are laid in a parallel configuration and covered with low density or medium density polyethylene (PE) or polyvinyl chloride (PVC)
Nominal Conductor Diameter |
mm |
0.9 |
1.0 |
1.023 |
Conductor Gauge Size |
AWG |
19 |
18.5 |
18 |
Conductor Size |
mm2 |
0.636 |
0.785 |
0.827 |
Minimum Insulation Resistance @500V DC |
MΩ.km / MΩ.kft |
30/100 |
30/100 |
30/100 |
Dielectric Strength Conductor to Conductor(3secs) |
V DC |
7050 |
7050 |
7050 |
Nominal Insulation Thickness |
mm/inch |
1.02/0.039 |
1.02/0.039 |
1.02/0.039 |
Nominal Insulated Conductor Diameter |
mm/inch |
2.94/0.116 |
3.04/0.117 |
3.06/0.118 |
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter
Cable Code | Number of Cores |
Insulation Material |
Nominal Insulation Thickness mm/inch |
Nominal Overall Dimensions mm/inch |
Nominal Weight kg/km / lbs/kft |
1.023mm Conductor, 3.06 Insulated Wire | |||||
2 |
PE |
1.02/0.04 |
3.0x7.0/0.11x0.28 |
32/22 |
|
2 |
PVC |
1.45/0.06 |
3.9x7.6/0.15x0.30 |
49/33 |
|
1.0mm Conductor, 3.04 Insulated Wire | |||||
TP7-Y-1P18/5A-SS | 2 | PVC | 1.02/0.04 | 3.9x7.4/0.15x0.29 | 46/31 |
0.9mm Conductor, 2.94 Insulated Wire | |||||
TP7-2Y-1P19A-SS | 2 | PE | 1.02/0.04 | 2.9x7.7/0.11x0.30 | 25/17 |