Contact Us

+852 2116 1040

+86 180 1862 7191

sales@caledonian-cables.com

Quick Contact

Hot

  • Fire Resistant Cables
  • EN50288-7 Cables
  • Composite Cables
  • EN50288-7 Cables

Certificate

  • Caledonian
  • Caledonian
  • Caledonian
  • Caledonian
  • Caledonian

Join the newsletter

Subscribe to get our latest content by email.

    We won't send you spam.

    Unsubscribe at any time.

    PE Insulated Category 3 UTP/FTP Cables

    Application

    The cables are designed for medium frequency data or telephone systems, suitable for indoor or outdoor insulations.

    Standards

    • TIA/EIA-568B
    • IEC 61156-4
    • UL-444
    • ANSI/ICEA S-80-576

    Construction

    Conductors

    Solid annealed bare copper sized 0.5mm (24 AWG) as per ASTM-B3/class 1 of IEC 60228

    Insulation

    Solid polyethylene as per ASTM D 1248/IEC 60708

    Twisted Pairs

    Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

    Cable Core Assembly

    The 50-pair cable is composed of 4 units having 12 or 13 pairs each. All other cables are composed of 25-pair units. Units are identified by colour coded binders

    Core Wrapping

    Non-hygroscopic dielectric tape fully enclosing the core with an overlap

    Screen (optional)

    An optional Aluminium/Polyester tape placed in contact with solid copper drain wire may be provided as an option

    Sheath

    PVC or LSZH

    Ripcord

    Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

    Electrical Properties

    Nominal Conductor Diameter

    mm

    0.5

    Maximum DC Resistance

    Ω/100m

    9.38

    Maximum Resistance Unbalance

    %

    5

    Maximum Capacitance Unbalance pair-to-ground @1KHz

    pF/100m

    330

    Minimum Worst Pair Structural Return Loss (SRL):

     

     

           Up to 10 MHz

    dB

    12

           Between 10 and 16 MHz

    dB

    10

    Impedance @1-16 MHz

    85 - 115

    Maximum Attenuation at 20°C

     

     

           @64KHz

    dB/100m

    0.9

           @256KHz

    dB/100m

    1.3

           @512KHz

    dB/100m

    1.8

           @772KHz

    dB/100m

    2.2

           @1MHz

    dB/100m

    2.6

           @4MHz

    dB/100m

    5.6

           @8MHz

    dB/100m

    8.5

           @10MHz

    dB/100m

    9.7

           @16MHz

    dB/100m

    13.1

    Minimum Worst pair-to-pair NEXT Loss

     

     

           @772KHz

    dB

    43

           @1MHz

    dB

    41

           @4MHz

    dB

    32

           @8MHz

    dB

    28

           @10MHz

    dB

    26

           @16MHz

    dB

    23

    Minimum Relative Velocity of Propagation @10MHz

    dB

    0.585

    Mechanical and Thermal Properties

    Temperature range during operation (fixed state): -30°C – +70°C
    Temperature range during installation (mobile state): -20°C – +50°C 
    Minimum bending radius: 10 x Overall Diameter (unarmoured cable);15 x Overall Diameter (armoured cables)

    Colour Code

    Standard Colour Code is per TIA/EIA 568B or ICEA S-80-576 as given in Colour Code Chart.

    Dimensions And Weight

    PE INSULATED CATEGORY 3 UTP CABLES

    Cable Code Number of Pairs Nominal Sheath
    Thickness
    mm
    Nominal Overall
    Diameter
    mm
    Nominal Weight
    kg/km
    0.5mm Conductor, 0.9mm Insulated Wire, UTP, PVC Sheathed, Indoor

    TP568-2YY-10P05-UTPC3

    10

    0.9

    9.5

    77

    TP568-2YY-25P05-UTPC3

    25

    0.9

    12.5

    155

    TP568-2YY-50P05-UTPC3

    50

    1.0

    17.0

    260

    TP568-2YY-100P05-UTPC3

    100

    1.1

    21.5

    530

    TP568-2YY-200P05-UTPC3

    200

    1.2

    29.5

    1100

    TP568-2YY-300P05-UTPC3

    300

    1.3

    33.5

    1550

    0.5mm Conductor, 0.9mm Insulated Wire, UTP, LSZH Sheathed, Indoor & Outdoor

    TP568-2YH-10P05-UTPC3

    10

    0.9

    10.0

    80

    TP568-2YH-25P05-UTPC3

    25

    0.9

    14.0

    150

    TP568-2YH-50P05-UTPC3

    50

    1.1

    16.5

    280

    TP568-2YH-100P05-UTPC3 100 1.4 21.5

    530

    TP568-2YH-200P05-UTPC3 200 1.7 30.0

    900

    TP568-2YH-300P05-UTPC3 300 1.7 36.0

    1300

    0.5mm Conductor, 0.9mm Insulated Wire, UTP, PE Sheathed, Outdoor
    TP568-2Y2Y-10P05-UTPC3 10 0.9 9.5

    80

    TP568-2Y2Y-25P05-UTPC3 25 0.9 13.0

    150

    TP568-2Y2Y-50P05-UTPC3 50 1.0 16.0

    280

    TP568-2Y2Y-100P05-UTPC3 100 1.1 21.5

    550

    TP568-2Y2Y-200P05-UTPC3 200 1.2 28.5

    1050

    TP568-2Y2Y-300P05-UTPC3 300 1.3 34.5

    1550

    PE INSULATED CATEGORY 3 FTP CABLES

    Cable Code

    Number of Pairs

    Nominal Sheath 
    Thickness mm

    Nominal Overall 
    Diameter 
    mm

    Nominal Weight kg/km

    0.5mm Conductor, 0.9mm Insulated Wire, FTP, PVC Sheathed, Indoor
    TP568-2Y(St)Y-10P05-FTPC3 10 0.9 10.0

    85

    TP568-2Y(St)Y-25P05-FTPC3 25 0.9 13.5

    170

    TP568-2Y(St)Y-50P05-FTPC3 50 1.0 17.0

    300

    TP568-2Y(St)Y-100P05-FTPC3 100 1.1 22.0

    570

    TP568-2Y(St)Y-200P05-FTPC3 200 1.2 30.0

    1120

    TP568-2Y(St)Y-300P05-FTPC3 300 1.3 36.6

    1630

    0.5mm Conductor, 0.9mm Insulated Wire, FTP, LSZH Sheathed, Indoor& Outdoor

    TP568-2Y(St)H-25P05-FTPC3 25 0.9 14.0

    170

    TP568-2Y(St)H-50P05-FTPC3 50 1.0 17.5

    300

    TP568-2Y(St)H-100P05-FTPC3 100 1.2 23.0

    580

    TP568-2Y(St)H-200P05-FTPC3 200 1.6 32.0

    1120

    TP568-2Y(St)H-300P05-FTPC3 300 1.6 35.0

    1320

    0.5mm Conductor, 0.9mm Insulated Wire, FTP, PE Sheathed, Outdoor

    TP568-2Y(St)2Y-10P05-FTPC3 10 0.9 11.0

    85

    TP568-2Y(St)2Y-25P05-FTPC3 25 0.9 13.5

    170

    TP568-2Y(St)2Y-50P05-FTPC3 50 1.0 16.5

    300

    TP568-2Y(St)2Y-100P05-FTPC3 100 1.1 22.6

    570

    TP568-2Y(St)2Y-200P05-FTPC3 200 1.2 31.0

    1070

    TP568-2Y(St)2Y-300P05-FTPC3 300 1.3 35.5

    1570

     

    Contact Us

    Add the link of current page.

    Clear

    Submit

    Instant Messaging

    WhatsApp :

    +852 6230 0392

    Skype :

    Caledonian Cables

    live:1cb87739a29fb08c

    Wechat :
    The personal information you enter is only used to reply to your message, It will not be leaked or used for other purposes.