    Colour Codes & Cable Make Up

    A) Colour Code According to IEC 189-3

    Standard Colours Easily Identifiable Combinations Less-easily Identifiable Combinations
    BLUE RED Black BROWN Black
    ORANGE RED BLUE ORANGE Black
    GREEN ORANGE GREEN ORANGE GREY
    BROWN ORANGE BLUE GREEN GREY
    GREY ORANGE VIOLET GREEN VIOLET
    WHITE YELLOW Black VIOLET Black
    RED YELLOW RED GREY Black
    Black YELLOW GREEN ** GREY VIOLET
    YELLOW YELLOW BLUE WHITE BROWN
    VIOLET YELLOW VIOLET WHITE ORANGE
    PINK GREEN Black WHITE VIOLET
    TURQUOISE GREEN RED GREEN BLUE
      BLUE Black BROWN BLUE
      GREY RED GREY BROWN
      GREY BLUE GREEN BROWN
      WHITE Black WHITE GREY
      WHITE RED ORANGE BROWN
      WHITE GREEN ORANGE RED
      WHITE BLUE RED BROWN
          WHITE YELLOW

    **NOTE: The colour YELLOW-Green should be reserved for earth or safety wires.

    B) Colour Code & Cable Make Up According to ICEA S-80-576

    Pair No. a-wire b-wire Pair No. a-wire b-wire
    1 WHITE BLUE BLUE WHITE 13 Black GREEN GREEN Black
    2 WHITE ORANGE ORANGE WHITE 14 Black BROWN BROWN Black
    3 WHITE GREEN GREEN WHITE 15 Black GREY GREY Black
    4 WHITE BROWN BROWN WHITE 16 YELLOW BLUE BLUE YELLOW
    5 WHITE GREY GREY WHITE 17 YELLOW ORANGE ORANGE YELLOW
    6 RED BLUE BLUE RED 18 YELLOW GREEN GREEN YELLOW
    7 RED ORANGE ORANGE RED 19 YELLOW BROWN BROWN YELLOW
    8 RED GREEN GREEN RED 20 YELLOW GREY GREY YELLOW
    9 RED BROWN BROWN RED 21 VIOLET BLUE BLUE VIOLET
    10 RED GREY GREY RED 22 VIOLET ORANGE ORANGE VIOLET
    11 Black BLUE BLUE Black 23 VIOLET GREEN GREEN VIOLET
    12 Black ORANGE ORANGE Black 24 VIOLET BROWN BROWN VIOLET
              25 VIOLET GREY GREY VIOLET

    In accordance with ICEA publication S-80-576-2002, the colour code is composed of ten (10) distinctive colours to identify 25 pairs. Marking of each mate of the primary conductor in a pair with the colour of that primary conductor is optional.

    When cables of larger than 25 pairs are required, the core shall be assembled into 25-pair sub-units, each colour coded in accordance with ICEA publication S-80-576. Cables with over 600 pairs shall have 25-pair binder groups combined into super units. These super units shall be wrapped with a solid colour thread that follows the primary colour scheme of white, red, black, yellow and violet. Binder colour code integrity shall be maintained wherever cables are spliced.

    C) Colour Code According to IEC 60189-2, BT210B

    Colour Scheme for Pairs & Triples

    Cabling Element No. a-wire b-wire Cabling Element No. a-wire b-wire Cabling Element No. a-wire b-wire
    1 WHITE BLUE 35 BLUE Black GREY 69 GREEN RED BROWN
    2 WHITE ORANGE 36 YELLOW BLUE BLUE 70 GREEN RED GREY
    3 WHITE GREEN 37 YELLOW BLUE ORANGE 71 GREEN Black BLUE
    4 WHITE BROWN 38 YELLOW BLUE GREEN 72 GREEN Black ORANGE
    5 WHITE GREY 39 YELLOW BLUE BROWN 73 GREEN Black GREEN
    6 RED BLUE 40 YELLOW BLUE GREY 74 GREEN Black BROWN
    7 RED ORANGE 41 WHITE ORANGE BLUE 75 GREEN Black GREY
    8 RED GREEN 42 WHITE ORANGE ORANGE 76 YELLOW GREEN BLUE
    9 RED BROWN 43 WHITE ORANGE GREEN 77 YELLOW GREEN ORANGE
    10 RED GREY 44 WHITE ORANGE BROWN 78 YELLOW GREEN GREEN
    11 BLACK BLUE 45 WHITE ORANGE GREY 79 YELLOW GREEN BROWN
    12 BLACK ORANGE 46 ORANGE RED BLUE 80 YELLOW GREEN GREY
    13 BLACK GREEN 47 ORANGE RED ORANGE 81 WHITE BROWN BLUE
    14 BLACK BROWN 48 ORANGE RED GREEN 82 WHITE BROWN ORANGE
    15 BLACK GREY 49 ORANGE RED BROWN 83 WHITE BROWN GREEN
    16 YELLOW BLUE 50 ORANGE RED GREY 84 WHITE BROWN BROWN
    17 YELLOW ORANGE 51 ORANGE Black BLUE 85 WHITE BROWN GREY
    18 YELLOW GREEN 52 ORANGE Black ORANGE 86 RED BROWN BLUE
    19 YELLOW BROWN 53 ORANGE Black GREEN 87 RED BROWN ORANGE
    20 YELLOW GREY 54 ORANGE Black BROWN 88 RED BROWN GREEN
    21 WHITE BLUE BLUE 55 ORANGE Black GREY 89 RED BROWN BROWN
    22 WHITE BLUE ORANGE 56 YELLOW ORANGE BLUE 90 RED BROWN GREY
    23 WHITE BLUE GREEN 57 YELLOW ORANGE ORANGE 91 BROWN Black BLUE
    24 WHITE BLUE BROWN 58 YELLOW ORANGE GREEN 92 BROWN Black ORANGE
    25 WHITE BLUE GREY 59 YELLOW ORANGE BROWN 93 BROWN Black GREEN
    26 RED BLUE BLUE 60 YELLOW ORANGE GREY 94 BROWN Black BROWN
    27 RED BLUE ORANGE 61 WHITE GREEN BLUE 95 BROWN Black GREY
    28 RED BLUE GREEN 62 WHITE GREEN ORANGE 96 YELLOW BROWN BLUE
    29 RED BLUE BROWN 63 WHITE GREEN GREEN 97 YELLOW BROWN ORANGE
    30 RED BLUE GREY 64 WHITE GREEN BROWN 98 YELLOW BROWN GREEN
    31 BLUE Black BLUE 65 WHITE GREEN GREY 99 YELLOW BROWN BROWN
    32 BLUE Black ORANGE 66 GREEN RED BLUE 100 YELLOW BROWN GREY
    33 BLUE Black GREEN 67 GREEN RED ORANGE 101 WHITE GREY BLUE
    34 BLUE Black BROWN 68 GREEN RED GREEN 102 WHITE GREY ORANGE

    Note 1: In each triple there shall be a c-wire, coloured TURQUOISE.

    Note 2: Uppercase letters indicate the base, solid colour of insulation, and the lower case indicates ink bands applied onto the base colour.

    Make-up & Unit Identification Colours – 20 Pair Unit

    Pair Size Cen-ter 1st Layer 2nd Layer 1 2 3 4 5 6 7 8 9-15 16
    20Pair No. of Unit 1     ORANGE                  
    40Pair 4x½     ORANGE GREEN                
    80Pair 1 6x½   ORANGE ORANGE NATURL GREEN            
    160Pair 4x½ 6   ORANGE GREEN ORANGE NATURL NATURL NATURL NATURL GREEN    
    320Pair 1 5 10 ORANGE ORANGE NATURL NATURL NATURL GREEN ORANGE NATURL NATURL GREEN

    Note 1: ½ refers to sub-units of 10 Pairs.

    D) Colour Code & Cable Make Up According to CW 1171, CW 1224, CW 1236

    Colour Scheme for Pairs

    Pair No. a-wire b-wire Pair No. a-wire b-wire
    1 WHITE BLUE 13 Black GREEN
    2 WHITE ORANGE 14 Black BROWN
    3 WHITE GREEN 15 Black GREY
    4 WHITE BROWN 16 YELLOW BLUE
    5 WHITE GREY 17 YELLOW ORANGE
    6 RED BLUE 18 YELLOW GREEN
    7 RED ORANGE 19 YELLOW BROWN
    8 RED GREEN 20 YELLOW GREY
    9 RED BROWN 21 VIOLET BLUE
    10 RED GREY 22 VIOLET ORANGE
    11 Black BLUE 23 VIOLET GREEN
    12 Black ORANGE 24 VIOLET BROWN
          25 VIOLET GREY

    Binder Colour Identification (Double & Quadruple Units)

    Unit Position of Sub-unit or Unit
    First Second Third Fourth
    Double BLUE BLUE ORANGE ORANGE
    Quadruple BLUE ORANGE GREEN BROWN

    Binder Colour Identification (Centre & Layers)

    Cable Size Nunber&Pair Sizes of Units in Centre and successive Layers No.of Pair in Spare Pair Unit No.of Unusable Pairs Allowed
    Centre 1st Layer 2nd Layer 3rd Layer
    50 1х50       0 1
    100 1х25
    1х100
    3х(12+13)     0 1
    200 1х50
    4х50
    6х25     4 2
    300 1х50
    1х100
    5х50
    8х25
        4 3
    400 1х100 6х50     4 3
    500 3х50
    1х100
    7х50
    8х50
        4 4
    600 3х50
    1х100
    9х50
    5х100
        4 4
    800 1х50
    4х50
    5х50
    6х100
    10х50   4 5
    1000 4х50
    3х100
    8х100
    7х100
        4 5
    1200 3х100
    4х100
    9х100
    8х100
        4 5
    1600 1х100 5х100 10х100   4 6
    2000 4х50 6х100 12х100   8 6
    2400 3х100 8х100 13х100   8 7
    3200 1х100 5х100 10х100 16х100 8 7
    4000 3х100 7х100 12х100 18х100 8 8
    4800 4х100 9х100 15х100 20х100 8 8

    Note: Alternative make-ups are shown for some sizes and as a further alternative any cable can be made-up using 25 Pair Units throughout.