    PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables (RF 0.1)

    Application

    The cables are designed to give good protection to the core against inductive interference (RF=0.1).The cables are used for outdoor signaling equipment.

    Standards

    • RENFE E.T. 03.365.051.6

    Construction

    Conductors

    Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

    Insulation

    Solid polyethylene as per ASTM D 1248/IEC 60708

    Cabling Element

    Four insulated conductors are twisted together to form a quad

    Cable Core Assembly

    The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders

    Core Wrapping

    One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

    Electrostatic Screen

    One layer of copper wires 0.12mm is applied helically

    Bedding

    PE or LSZH

    Electrostatic Armour

    Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one

    Sheath

    PE/PVC or LSZH

    Ripcord

    Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

    Electrical & Mechanical Properties

    Nominal Conductor Diameter

    mm

    0.9

    1.4

    Conductor Size

    mm2

    0.636

    1.539

    Maximum Conductor Resistance @20°C

    Ω/km

    28

    12.1

    Minimum Insulation Resistance @500V DC

    MΩ.km

    35000

    5000

    Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km

     

    0.1

    0.1

                                         Induced Voltage Em 500V/Km   0.16 0.16

    Maximum Resistance Unbalance

    %

    2.5

    2.5

    Maximum Mutual Capacitance @0.8KHz

    nF/km

    45

    50

    Maximum Capacitance Unbalance @1KHz pair-to-pair

    pF/500m

    250

    250

    Maximum Capacitance Unbalance @1KHz pair-to-ground

    pF/500m

    1200

    1200

    Maximum Average Attenuation @1KHz

    dB/km

    0.7

    0.46

    Maximum Average Attenuation @10KHz

    dB/km

    1.6

    0.85

    Maximum Average Attenuation @20KHz

    dB/km

    2.1

    1.3

    Dielectric Strength Conductor to Conductor 3secs

    V DC

    3000

    3000

                               Conductor to Screen 3secs V DC 3500 3500

    Minimum Insulation Thickness

    mm

    0.45

    0.65

    Maximum Insulated Conductor Diameter

    mm

    1.8

    2.7

    Mechanical and Thermal Properties

    Temperature range during operation (fixed state): -30°C – +70°C
    Temperature range during installation (mobile state): -20°C – +50°C 
    Minimum bending radius: 15 x Overall Diameter

    Colour Code

    Layer Quad Position Colour of conductors
    1 2 3 4
    Centre and even layers First ORANGE

    GREEN

    RED

    WHITE
    Even YELLOW

    GREEN

    BLUE

    WHITE

    Odd

    YELLOW

    GREEN

    RED

    WHITE

    Last

    ORANGE

    GREEN

    BLUE

    WHITE

    Odd Layers

    First ORANGE

    GREEN

    RED

    BLACK
    Even YELLOW

    GREEN

    BLUE

    BLACK

    Odd

    YELLOW

    GREEN

    RED

    BLACK

    Last

    ORANGE

    GREEN

    BLUE

    BLACK

    Dimensions And Weight

    Cable Code

    Number of Quads

    Nominal Bedding/Sheath Thickness 
    mm

    Nominal Overall 
    Diameter 
    mm

    Nominal Weight kg/km

    0.9mm Conductor, 1.8mm Insulated Wire
    TP365-2Y(CTS)2Y(DSTA)Y1Q09-RF01 1 1.5/1.6 24.5

    1300

    TP365-2Y(CTS)2Y(DSTA)Y3Q09-RF01 3 1.5/1.6 25.5

    1425

    TP365-2Y(CTS)2Y(DSTA)Y5Q09-RF01 5 1.5/1.6 28.0

    1650

    TP365-2Y(CTS)2Y(DSTA)Y7Q09-RF01 7 1.5/1.6 29.5

    1800

    TP365-2Y(CTS)2Y(DSTA)Y25Q09-RF01 25 1.7/1.8 41.0

    3175

    1.4mm Conductor, 2.7mm Insulated Wire
    TP365-2Y(CTS)2Y(DSTA)Y3Q14-RF01 3 1.5/1.6 28.5

    1775

    TP365-2Y(CTS)2Y(DSTA)Y5Q14-RF01 5 1.6/1.8 33.0

    2200

    TP365-2Y(CTS)2Y(DSTA)Y7Q14-RF01 7 1.6/1.8 35.5

    2525

    TP365-2Y(CTS)2Y(DSTA)Y10Q14-RF01 10 1.6/1.8 39.0

    2975

     

    Contact Us

    Add the link of current page.

    Clear

    Submit

    Instant Messaging

    WhatsApp :

    +852 6230 0392

    Skype :

    Caledonian Cables

    live:1cb87739a29fb08c

    Wechat :
    The personal information you enter is only used to reply to your message, It will not be leaked or used for other purposes.