Quick Contact
The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.
• RENFE E.T. 03.365.051.6
Construction
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Solid polyethylene as per ASTM D 1248/IEC 60708
Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap
PE or LSZH
Corrugated copper tape of 0.12mm is applied longitudinally with overlap
Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
PVC or LSZH
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Nominal Conductor Diameter |
mm |
0.9 |
1.4 |
Conductor Size |
mm2 |
0.636 |
1.539 |
Maximum Conductor Resistance @20°C |
Ω/km |
28 |
12.1 |
Minimum Insulation Resistance @500V DC |
MΩ.km |
35000 |
5000 |
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km |
|
0.3 |
0.3 |
Induced Voltage Em 500V/Km | 0.5 | 0.5 | |
Maximum Resistance Unbalance |
% |
2.5 |
2.5 |
Maximum Mutual Capacitance @0.8KHz |
nF/km |
59 |
64 |
Maximum Capacitance Unbalance @1KHz pair-to-pair |
pF/500m |
275 |
275 |
Maximum Capacitance Unbalance @1KHz pair-to-ground |
pF/500m |
1200 |
1200 |
Maximum Average Attenuation @1KHz |
dB/km |
0.7 |
0.46 |
Maximum Average Attenuation @10KHz |
dB/km |
1.6 |
0.85 |
Maximum Average Attenuation @20KHz |
dB/km |
2.1 |
1.3 |
Dielectric Strength Conductor to Conductor 1 min |
V DC |
1500 |
1500 |
Conductor to Screen 1min | V DC | 2000 | 2000 |
Dielectric Strength Conductor to Conductor 3secs | V DC | 3000 | 3000 |
Conductor to Screen 3secs | V DC | 4500 | 4500 |
Nominal Insulation Thickness |
mm |
0.45 |
0.65 |
Nominal Insulated Conductor Diameter |
mm |
1.8 |
2.7 |
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Position | Number of pairs | |||||||||
1(Pilot) | 2(Direct) | 3 | 4 | 5 | ||||||
Centre |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
|
|
Layers |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
GREEN |
NATURAL |