    PE Insulated Air Core/Jelly Filled Paired Railway Signalling Cables (RF 0.3)

    Application

    The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.

    Standards

    • RENFE E.T. 03.365.051.6

    Construction

    Conductors

    Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

    Insulation

    Solid polyethylene as per ASTM D 1248/IEC 60708

    Twisted Pairs

    Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk

    Cable Core Assembly

    The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders

    Core Filling (optional)

    The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable

    Core Wrapping

    One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

    Moisture Barrier (optional)

    An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap

    Bedding

    PE or LSZH

    Electrostatic Screen

    Corrugated copper tape of 0.12mm is applied longitudinally with overlap

    Electrostatic Armour

    Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one

    Sheath

    PVC or LSZH

    Ripcord

    Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

    Electrical Properties

    Nominal Conductor Diameter

    mm

    0.9

    1.4

    Conductor Size

    mm2

    0.636

    1.539

    Maximum Conductor Resistance @20°C

    Ω/km

    28

    12.1

    Minimum Insulation Resistance @500V DC

    MΩ.km

    35000

    5000

    Reduction Factor Rk (50Hz)  Induced Voltage Em 100V/Km

     

    0.3

    0.3

                                          Induced Voltage Em 500V/Km   0.5 0.5
    Maximum Resistance Unbalance

    %

    2.5

    2.5

    Maximum Mutual Capacitance @0.8KHz

    nF/km

    59

    64

    Maximum Capacitance Unbalance @1KHz pair-to-pair

    pF/500m

    275

    275

    Maximum Capacitance Unbalance @1KHz pair-to-ground

    pF/500m

    1200

    1200

    Maximum Average Attenuation @1KHz

    dB/km

    0.7

    0.46

    Maximum Average Attenuation @10KHz

    dB/km

    1.6

    0.85

    Maximum Average Attenuation @20KHz

    dB/km

    2.1

    1.3

    Dielectric Strength Conductor to Conductor 1 min

    V DC

    1500

    1500

                              Conductor to Screen 1min   V DC 2000 2000
    Dielectric Strength Conductor to Conductor 3secs  V DC 3000 3000
                              Conductor to Screen 3secs   V DC 4500 4500
    Nominal Insulation Thickness

    mm

    0.45

    0.65

    Nominal Insulated Conductor Diameter

    mm

    1.8

    2.7

    Mechanical and Thermal Properties

    Temperature range during operation (fixed state): -30°C – +70°C
    Temperature range during installation (mobile state): -20°C – +50°C 
    Minimum bending radius: 15 x Overall Diameter

    Colour Code

    Position Number of pairs
    1(Pilot) 2(Direct) 3 4 5

    Centre

    BLACK

    NATURAL

    BLUE

    NATURAL

    YELLOW

    NATURAL

    RED

    NATURAL

     

     

    Layers

    BLACK

    NATURAL

    BLUE

    NATURAL

    YELLOW

    NATURAL

    RED

    NATURAL

    GREEN

    NATURAL

    Dimensions And Weight

    Cable Code

    Number of Pairs

    Nominal Bedding/ Sheath Thickness mm

    Nominal Overall 
    Diameter 
    mm

    Nominal Weight kg/km

    0.9mm Conductor, 1.8mm Insulated Wire
    TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 2 1.5/1.6 18.3

    1300

    TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 6 1.5/1.6 21.7

    1425

    TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 10 1.5/1.6 25.2

    1650

    TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 14 1.5/1.6 26.7

    1800

    TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 20 1.5/1.6 29.2

    2275

    TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 28 1.6/1.8 32.3

    2450

    TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 38 1.7/1.8 36.0

    2895

    TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 54 1.7/1.8 40.5

    3275

    TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 74 1.8/2.0 45.6

    3775

    TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 96 1.9/2.0 49.8

    4275

    1.4mm Conductor, 2.7mm Insulated Wire
    TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 2 1.5/1.6 20.2

    1615

    TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 6 1.5/1.6 25.7

    1775

    TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 10 1.6/1.8 30.8

    2200

    TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 14 1.6/1.8 32.8

    2525

    TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 20 1.7/1.8 36.5

    2975

    TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 28 1.7/1.8 40.5

    3150

    TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 38 1.8/2.0 45.6

    3695

    TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 58 2.0/2.2 52.3

    3975

    TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 74 2.1/2.2 59.1

    4475

    TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 96 2.2/2.3 66.0