    ADSL Connecting Cables

    Application

    The cables are designed for ADSL transmission system. The cables are characterized by guaranteed data speeds up to 10MHz. The cables have a small cable diameter with an easily removable sheath.

    Standards

    • IEC 61156-1 Part 1

    • ANSI/ICEA S-80-576

    Construction

    Conductors

    Solid annealed bare copper sized 0.4mm as per ASTM B-3/IEC 60228 Class 1

    Insulation

    Solid polyethylene as per ASTM D 1248/IEC 60708

    Twisted Pairs

    Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

    Cable Core Assembly

    The pairs are cabled in concentric layer to form the cable core

    Core Wrapping

    One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

    Screen

    An aluminium polyester foil is applied in close contact with tinned copper braid screen

    Sheath

    PVC or LSZH compound

    Ripcord

    Ripcord may be placed to facilitate sheath removal

    Electrical Properties

    Number of Pairs

     

    24

    32

    64

    72

    96

    128

    Maximum Conductor Resistance @20°C

    Ω/km

    143

    143

    143

    143

    143

    143

    Minimum Insulation Resistance @500V DC

    MΩ.km

    1000

    1000

    1000

    1000

    1000

    1000

    Maximum Mutual Capacitance @800Hz

    nF/km

    80

    80

    80

    80

    80

    80

    Maximum Capacitance Unbalance pair-to-pair

    pF/500m

    250

    250

    250

    250

    250

    250

    Impedance

    120

    120

    105

    105

    100

    105

    Maximum Average Attenuation @1MHz

    dB/km

    32

    32

    32

    32

    32

    32

    Maximum Average Attenuation @10MHz

    dB/km

    110

    110

    110

    110

    110

    110

    Minimum NEXT pair-to-pair @1MHz

    dB

    55

    55

    55

    55

    55

    55

    Minimum NEXT pair-to-pair @10MHz

    dB

    40

    40

    40

    40

    40

    40

    Dielectric Strength 1min

    V DC

    1500

    1500

    1500

    1500

    1500

    1500

    Mechanical and Thermal Properties

    Temperature range during operation (fixed state): -30°C – +70°C
    Temperature range during installation (mobile state): -20°C – +50°C
    Minimum bending radius: 10 x Overall Diameter

    Colour Code

    Standard colour code is per ANSI/ICEA S-80-576 given in Colour Code Chart

    Dimensions And Weight

    Cable Code

    Number of Pairs

    Nominal Insulation 
    Thickness mm

    Nominal Sheath 
    Thickness mm

    Nominal Overall 
    Diameter 
    mm

    Nominal Weight kg/km

    TP576-2Y(St)Y-24P04-ADSL

    24 / 3X4Q

    0.2

    0.9

    11.0

    139

    TP576-2Y(St)Y-32P04-ADSL

    32 / 4X4Q

    0.2

    0.9 12.0

    180

    TP576-2Y(St)Y-64P04-ADSL

    64 0.15 1.0 15.0

    300

    TP576-2Y(St)Y-72P04-ADSL

    72 0.15 1.0 16.0

    330

    TP576-2Y(St)Y-96P04-ADSL

    96 0.15 1.1 19.5

    450

    TP576-2Y(St)Y-128P04-ADSL

    128 0.15 1.2 20.0

    528

     