Submersible Cable for drinking water (round type)

Cable Application

These cables are designed for making connections to submersible pumps in drinking water. It can also be used in industrial water.

Standard

  • DIN VDE 0282, part 16
  • DIN VDE 0295
  • IEC 60228
  • DIN VDE 0298
  • DIN VDE 0472

Construction

Conductor Bare copper stranded class 5 to VDE0295, IEC 60228.
Insulation EPR type 3GI3. Cross-linked EPDM can be offered upon request.
Outer Sheath EPR type 3GM2, coloured blue. Cross-linked EPDM can be offered upon request.

Technical data

Test Voltage 50Hz, 5 min 2500V
Rated Voltage 450/750V
Maximum admissible conductor Temperature in Operation 90°C
Short Circuit Temperature 250°C
Temperature Range -40°C~+60°C

Dimensions

No. of cores × cross-sectional area Overall Diameter Weight
Min. mm Max. mm kg/km
1×1.5 5.8 7.2 54
1×2.5 6.4 8.0 76
1×4 7.4 9.0 105
1×6 8.0 11.0 135
1×10 9.8 12.5 200
1×16 11.0 14.5 290
1×25 12.5 16.5 410
1×35 14.0 18.5 560
1×50 16.5 21.0 740
1×70 18.5 23.5 1000
1×95 21.0 26.0 1300
1×120 23.5 28.5 1650
1×150 26.0 31.5 2000
1×185 27.5 34.5 2500
1×240 30.5 38.0 3100
1×300 33.5 41.5 3700
2×1.5 9.0 11.5 130
2×2.5 10.5 13.5 190
2×4 12.0 15.0 260
2×6 13.5 18.5 350
2×10 18.5 24.0 550
2×16 21.0 27.5 900
2×25 25.0 31.5 1300
3×1.5 9.6 12.5 150
3×2.5 11.5 14.5 220
3×4 13.0 16.0 340
3×6 14.5 20.0 480
3×10 20.0 25.5 750
3×16 22.5 29.5 1100
3×25 26.5 34.0 1450
3×35 29.5 38.0 2100
3×50 34.5 44.0 2800
3×70 39.0 49.5 3800
3×95 44.0 54.6 4600
3×120 47.5 59.0 5400
4G1.5 10.5 13.5 190
4G2.5 12.5 15.5 280
4G4 14.5 18.0 390
4G6 16.5 22.0 520
4G10 22.5 24.5 950
4G16 26.5 28.5 1400
4G25 32.0 34.0 1950
4G35 33.0 42.5 2700
4G50 38.0 48.5 3600
4G70 43.0 54.5 4900
4G95 50.0 60.5 6200
4G120 53.0 65.5 7200
5G1.5 11.5 15.0 230
5G2.5 13.5 17.0 340
5G4 16.0 19.5 470
5G6 18.0 24.5 640
5G10 24.0 30.5 1150
5G16 27.0 35.5 1700
7G1.5 16.5 17.5 370
10G1.5 18.6 19.6 460
7G2.5 18.9 19.4 510
10G2.5 21.4 21.9 650