Quick Contact
These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2016
Conductors : 18AWG solid bare copper.
Insulation : Foam PE.
Shielding1 : Al/Polyester/Al tape.
Shielding2 : Tinned copper braid.
Bedding : Low smoke and halogen-free polyolefin, coloured black.
Armour : Tinned copper wire braid.
Outer Sheath : Low smoke and halogen-free polyolefin.
AWG | 18 | |
---|---|---|
Nominal Conductor Diameter | mm | 1.0 |
Impedance | Ω | 75+/-5 |
Nominal Attenuation@100MHz | dB/100m | 6.9 |
Nominal Attenuation@200MHz | dB/100m | 9.0 |
Nominal Attenuation@300MHz | dB/100m | 11.8 |
Nominal Attenuation@400MHz | dB/100m | 13.1 |
Nominal Attenuation@500MHz | dB/100m | 15.4 |
Nominal Attenuation@900MHz | dB/100m | 21.5 |
Nominal Attenuation@1700MHz | dB/100m | 29.4 |
Capacitance | pF/m | 53.5 |
Velocity of Propagation | % | 83 |
Conductor DCR | Ω/km | 21.4 |
Shield DCR | Ω/km | 7.5 |
Inductance | μH/m | 0.32 |
Time Delay | ns/m | 4 |
Bending Radius : 15×OD
Temperature Range : -30℃ ~ +75℃
Nominal Inner Conductor Diameter | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
---|---|---|---|---|
mm | mm | mm | mm | kg/km |
1.0 | 1.8 | 1.2 | 11.2 | 208 |