    0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables

    • BS 6883,BS 7917,0.6/1kV,Offshore Marine Cables

    Application and Description

    These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

    Standards

    BS 7917

    IEC 60331-31 Fire resistant

    IEC 60332-3A Flame retardant

    IEC 60754-1; IEC 60754-2 Corrosivity

    IEC 61034-2 Smoke density

    Cold bend and impact (-40°C) (on request)

    CSA C22.2 No. 38-95 (on request)

    Construction

    Conductor : Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.

    Insulation : Mica tape + HF-EPR GP4 according to BS 7655 1.2.

    Inner Sheath : Halogen free thermosetting compound SB1 according to BS 7917.

    Armour : Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.

    Outer Sheath : Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

    Mechanical and Thermal Properties

    Minimum Internal Bending Radius : 6×OD

    Temperature Range : -40℃ ~ +90℃

    Dimensions and Weight

    Single core cables

    Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
    mm² mm mm mm mm mm mm mm mm kg/km
    1×4 1.0 1.0 6.7 8.0 0.3 1.1 10.2 12.1 245
    1×6 1.0 1.0 7.2 8.5 0.3 1.1 10.8 12.6 275
    1×10 1.0 1.0 8.1 9.5 0.3 1.2 11.9 13.8 355
    1×16 1.0 1.1 9.3 10.7 0.3 1.2 13.1 15.0 440
    1×25 1.2 1.2 11.5 13.2 0.3 1.3 15.4 17.7 600
    1×35 1.2 1.2 12.3 14.1 0.3 1.4 16.5 18.8 720
    1×50 1.4 1.3 14.1 15.9 0.3 1.4 18.2 20.6 910
    1×70 1.4 1.3 15.8 17.8 0.3 1.5 20.2 23.0 1170
    1×95 1.6 1.4 18.1 20.2 0.3 1.6 22.6 25.6 1510
    1×120 1.6 1.5 20.0 22.4 0.3 1.7 24.7 27.7 1830
    1×150 1.8 1.6 22.0 24.6 0.3 1.8 26.9 30.1 2160
    1×185 2.0 1.7 24.4 27.0 0.45 1.9 30.2 33.9 2790
    1×240 2.2 1.8 27.5 30.3 0.45 2.0 33.5 37.3 3530
    1×300 2.4 1.9 30.4 33.6 0.45 2.1 36.6 40.5 4280

    Multicore cables

    Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
    mm² mm mm mm mm mm mm mm mm kg/km
    2×1.5 0.8 1.1 9.0 10.4 0.3 1.2 12.7 14.7 310
    2×2.5 0.8 1.1 9.8 11.4 0.3 1.2 13.6 15.5 355
    2×4 1.0 1.2 11.8 13.5 0.3 1.3 15.7 18.0 475
    2×6 1.0 1.2 12.9 14.6 0.3 1.4 17.0 19.3 580
    2×10 1.0 1.3 14.9 16.8 0.3 1.4 19.0 21.4 750
    2×16 1.0 1.4 17.1 19.1 0.3 1.5 21.4 24.3 980
    2×25 1.2 1.5 21.2 23.7 0.3 1.7 25.9 29.0 1380
    2×35 1.2 1.6 23.1 25.7 0.3 1.8 28.0 31.2 1710
    2×50 1.4 1.7 26.5 29.2 0.45 2.0 32.5 36.3 2370
    2×70 1.4 1.9 30.3 33.5 0.45 2.1 36.5 40.5 3100
    2×95 1.6 2.1 34.9 38.2 0.45 2.3 41.4 46.0 4020
    2×120 1.6 2.2 38.4 42.2 0.45 2.5 45.4 50.1 4870
    3×1.5 0.8 1.1 9.6 11.0 0.3 1.2 13.3 15.3 345
    3×2.5 0.8 1.1 10.4 12.1 0.3 1.3 14.4 16.4 405
    3×4 1.0 1.2 12.6 14.3 0.3 1.3 16.5 18.8 540
    3×6 1.0 1.2 13.8 15.5 0.3 1.4 17.9 20.2 660
    3×10 1.0 1.3 15.9 17.8 0.3 1.5 20.2 23.0 910
    3×16 1.0 1.4 18.2 20.3 0.3 1.6 22.8 25.7 1200
    3×25 1.2 1.6 22.9 25.4 0.3 1.8 27.8 30.9 1760
    3×35 1.2 1.7 24.9 27.6 0.45 1.9 30.7 34.4 2260
    3×50 1.4 1.8 28.5 31.3 0.45 2.0 34.5 38.4 2880
    3×70 1.4 2.0 32.7 35.9 0.45 2.2 39.0 43.5 3800
    3×95 1.6 2.2 37.5 41.0 0.45 2.4 44.3 48.9 4890
    3×120 1.6 2.3 41.3 45.3 0.45 2.6 48.5 53.7 6070
    3×150 1.8 2.5 45.8 49.9 0.45 2.8 53.3 58.7 7270
    3×185 2.0 2.7 50.9 55.5 0.45 3.0 58.8 64.9 8970
    3×240 2.2 2.9 57.5 62.4 0.45 3.2 65.8 72.2 1350
    4×1.5 0.8 1.1 10.5 12.1 0.3 1.3 14.4 16.4 395
    4×2.5 0.8 1.1 11.4 13.1 0.3 1.3 15.4 17.6 465
    4×4 1.0 1.2 13.8 15.6 0.3 1.4 17.9 20.3 640
    4×6 1.0 1.3 15.3 17.3 0.3 1.5 19.6 22.5 790
    4×10 1.0 1.4 17.7 19.7 0.3 1.6 22.2 25.1 1070
    4×16 1.0 1.5 20.3 22.8 0.3 1.7 25.0 28.1 1460
    4×25 1.2 1.7 25.5 28.1 0.45 1.9 31.3 35.0 2140
    4×35 1.2 1.8 27.7 30.5 0.45 2.0 33.7 37.5 2670
    4×50 1.4 1.9 31.8 35.0 0.45 2.2 38.1 42.1 3630
    4×70 1.4 2.1 36.3 39.7 0.45 2.4 43.1 47.7 4740
    4×95 1.6 2.3 41.7 45.7 0.45 2.6 48.9 54.1 6290
    4×120 1.6 2.5 46.2 50.3 0.45 2.8 53.7 59.2 7670
    5×1.5 0.8 1.1 11.4 13.1 0.3 1.3 15.4 17.6 455
    7×1.5 0.8 1.2 12.6 14.4 0.3 1.3 16.6 18.9 530
    12×1.5 0.8 1.3 16.8 18.8 0.3 1.5 21.2 24.0 790
    19×1.5 0.8 1.4 19.9 22.4 0.3 1.6 24.4 27.5 1080
    27×1.5 0.8 1.6 24.3 26.9 0.3 1.8 29.2 32.8 1460
    37×1.5 0.8 1.7 27.4 30.4 0.45 1.9 33.2 37.0 1990
    5×2.5 0.8 1.2 12.7 14.4 0.3 1.3 16.6 18.9 560
    7×2.5 0.8 1.2 13.9 15.6 0.3 1.4 18.0 20.3 650
    12×2.5 0.8 1.4 18.7 20.8 0.3 1.6 23.2 26.2 970
    19×2.5 0.8 1.5 22.1 24.7 0.3 1.7 26.8 30.0 1360