These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industryplants, power plants, natural gas and petroluem plants, etc. These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet l°Cations; on racks, trays, in conduits.
Basic design to EN 50288-7
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation(Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance | ICEA S-73-532** |
Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.
300V
Conductor Area Size | mm2 | 0.5 | 0.75 | 1.0 | 1.3 | 1.5 | |
Insulation thickness (nominal) | mm | 0.35 | 0.38 | 0.4 | 0.45 | 0.45 | |
Conductor resistance (20°C) | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | |
Insulation resistance (20°C) | MΩ.km(Min.) | 5000 | |||||
Mutual Capacitance (1 kHz) | pF/m(Max.) | 115 | |||||
Capacitance unbalance(1 kHz) | pF/500 m (Max.) | 500 | |||||
L / R (ratio) (max.) | μH/Ω | 25 | 25 | 25 | 40 | 40 | |
Inductance | mH/km(Max.) | 1 | 1 | 1 | 1 | 1 | |
Operating voltage Urms | V | 300 | |||||
Test Voltage | Core to Core | V | 1500 | ||||
Core to Screen | V | 1500 |
Caledonian Cable Code | RE-2Y(St)HSWAH | |||||||
---|---|---|---|---|---|---|---|---|
No. of Triples x3xCross Section | Nominal Insulation Thick- ness | Nominal Inner Sheath Thick-ness | Nominal Overall Diameter Over InnerSheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thick-ness | Nominal Overall Diameter | Approx. Weight | |
No.x3xmm2 | mm | mm | mm | mm | mm | mm | kg/km | |
RE-2Y(St)HSWAH 1T0.5 | 1x3x0.50 | 0.35 | 0.8 | 5.4 | 0.9 | 1.3 | 9.8 | 200 |
RE-2Y(St)HSWAH 1T0.75 | 1x3x0.75 | 0.38 | 0.9 | 6.1 | 0.9 | 1.3 | 10.5 | 220 |
RE-2Y(St)HSWAH 1T1.0 | 1x3x1.0 | 0.4 | 0.9 | 6.6 | 0.9 | 1.3 | 11.0 | 244 |
RE-2Y(St)HSWAH 1T1.3 | 1x3x1.3 | 0.45 | 0.9 | 7.2 | 0.9 | 1.3 | 11.6 | 268 |
RE-2Y(St)HSWAH 1T1.5 | 1x3x1.5 | 0.45 | 0.9 | 7.5 | 0.9 | 1.3 | 11.9 | 277 |