    THHN/THWN, 600V, Type TC control Cable

    Application

    Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire. Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations. 130°C for emergency overload ratings, and 250°C for short circuit ratings. Not recommended in D.C. operation in wet locations.

    Compliances

    • NFPA 70 (NEC)
    • UL 1581 - Electrical Wires, Cables and Flexible Cords
    • ICEA S-58-679 - Control Cable Conductor Identification Method 1, Table 2
    • UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)

    Construction

    Conductor Soft annealed bare copper, Class B stranding per ASTM B8
    Insulation Polyvinyl chloride (PVC) insulation over with a nylon (polyamide) jacket applied
    Ground Wire Soft annealed bare copper, Class B stranding per ASTM B8
    Assembly Three or more conductors will be cabled round with fillers and a nylon rip cord is put under the jacket for ease of stripping
    Jacket Heat retardant, moisture and sunlight resistant PVC
    Color Upon request, black is preferable

    Parameters

    Insulation thickness 16-12AWG PVC 15mils(0.38mm) Nylon 4mils(0.10mm)
    10AWG PVC 20mils(0.50mm) Nylon 4mils(0.10mm)

    AWG 16 (26 strands) - Type TC-TFFN* Conductors

    Number of Conductors Nominal jacket thickness Nominal Overall Diameter Cable weight
    Inch/mm Inch/mm Lbs/kft kg/km
    2 0.045 1.14 0.288 7.32 43 64
    3 0.045 1.14 0.303 7.70 53 79
    4 0.045 1.14 0.329 8.36 66 98
    5 0.045 1.14 0.357 9.07 81 120
    7 0.045 1.14 0.386 9.80 103 153
    9 0.045 1.14 0.447 11.35 134 199
    12 0.045 1.14 0.501 12.73 165 245
    15 0.060 1.52 0.585 14.86 218 324
    19 0.060 1.52 0.614 15.60 263 391
    25 0.060 1.52 0.713 18.11 339 504
    30 0.080 2.03 0.753 19.13 396 589
    37 0.080 2.03 0.812 20.62 477 709

    AWG 14 (7 strands) - Type TC-THHN or THWN Conductors

    Number of Conductors Nominal jacket thickness Nominal Overall Diameter Cable weight
    Inch/mm Inch/mm Lbs/kft kg/km
    2 0.045 1.14 0.305 7.8 56 83
    3 0.045 1.14 0.322 8.2 74 110
    4 0.045 1.14 0.350 8.9 93 139
    5 0.045 1.14 0.381 9.7 109 162
    6 0.045 1.14 0.413 10.5 129 192
    7 0.045 1.14 0.413 10.5 145 215
    8 0.045 1.14 0.446 11.3 164 243
    9 0.045 1.14 0.478 12.2 182 271
    10 0.060 1.52 0.550 14.0 217 322
    12 0.060 1.52 0.568 14.4 251 373
    15 0.060 1.52 0.627 15.9 305 454
    19 0.060 1.52 0.658 16.7 373 555
    20 0.060 1.52 0.691 17.6 393 584
    25 0.060 1.52 0.766 19.4 483 719
    30 0.060 1.52 0.810 20.6 568 845
    37 0.080 2.03 0.913 23.2 720 1072

    AWG 12 (7 strands) - Type TC-THHN or THWN Conductors

    Number of Conductors Nominal jacket thickness Nominal Overall Diameter Cable weight
    Inch/mm Inch/mm Lbs/kft kg/km
    2 0.045 1.14 0.340 8.6 75 112
    3 0.045 1.14 0.360 9.2 105 156
    4 0.045 1.14 0.392 10.0 128 190
    5 0.045 1.14 0.428 10.9 154 229
    6 0.045 1.14 0.466 11.8 183 272
    7 0.045 1.14 0.466 11.8 207 308
    8 0.045 1.14 0.504 12.8 234 349
    9 0.060 1.52 0.572 14.5 277 412
    10 0.060 1.52 0.621 15.8 307 457
    12 0.060 1.52 0.641 16.3 358 532
    15 0.060 1.52 0.710 18.0 438 652
    19 0.060 1.52 0.746 18.9 539 802
    20 0.060 1.52 0.785 19.9 568 845
    25 0.080 2.03 0.911 23.1 734 1092
    30 0.080 2.03 0.963 24.4 863 1284
    37 0.080 2.03 1.036 26.3 1044 1553

    AWG 10 (7 strands) Type TC-THHN or THWN Conductors

    Number of Conductors Nominal jacket thickness Nominal Overall Diameter Cable weight
    Inch/mm Inch/mm Lbs/kft kg/km
    2 0.045 1.14 0.407 10.3 111 166
    3 0.045 1.14 0.433 11.0 155 230
    4 0.045 1.14 0.473 12.0 198 294
    5 0.060 1.52 0.549 13.9 250 371
    6 0.060 1.52 0.596 15.1 294 437
    7 0.060 1.52 0.596 15.1 333 495
    8 0.060 1.52 0.645 16.4 377 561
    9 0.060 1.52 0.693 17.6 421 626
    10 0.060 1.52 0.755 19.2 467 694
    12 0.060 1.52 0.780 19.8 547 814
    15 0.080 2.03 0.908 23.1 706 1050
    19 0.080 2.03 0.954 24.2 867 1291
    20 0.080 2.03 1.003 25.5 913 1359
    25 0.080 2.03 1.112 28.2 1125 1675
    30 0.080 2.03 1.177 29.9 1329 1977
    37 0.080 2.03 1.271 32.3 1614 2402