    EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded 25KV and 35KV, UL Type MV-105, 133% / 100% Ins. Levels, 345 Mils

    Applications

    These cables are suitable for use in wet or dry locations when installed in accordance with NEC, use in aerial, conduit, open tray and underground duct installations and use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5). Besides, they are installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    Meets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method

    Optional Flame Tests:

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation colored to contrast with black conducting shield layers.

    Composite Insulation Shield and Jacket : Six corrugated copper drain wires embedded in composite layers of semi-conducting thermoset copolymer and semi-conducting black flame-retardant Chlorinated Polyethylene (CPE).

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Groud Wire Nominal Jacket Thickness Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. Max. AWG Inches mm Inches mm LBS/1000FT kg/km In Air GND. Direct Burial
    Inches mm Inches mm
    1/0 0.34 8.89 1.020 25.91 1.120 28.45 17 0.080 2.03 1.29 32.77 1014 1509 215 215 295
    2/0 0.38 9.65 1.060 26.92 1.160 29.46 17 0.080 2.03 1.36 34.54 1163 1731 255 245 335
    3/0 0.43 10.92 1.105 28.07 1.205 30.61 17 0.080 2.03 1.41 35.81 1310 1949 290 275 380
    4/0 0.48 12.19 1.160 29.46 1.260 32.00 17 0.080 2.03 1.43 36.32 1442 2146 330 315 435
    250 0.53 13.46 1.210 30.73 1.315 33.40 16 0.080 2.03 1.51 38.35 1645 2448 365 345 475
    350 0.62 15.75 1.310 33.27 1.410 35.81 16 0.080 2.03 1.60 40.64 2024 3012 440 415 575
    500 0.74 18.80 1.430 36.32 1.530 38.86 16 0.080 2.03 1.74 44.20 2608 3881 535 500 700
    750 0.91 23.11 1.610 40.89 1.710 43.43 16 0.110 2.79 1.95 49.78 3596 5351 655 610 865
    1000 1.06 26.92 1.760 44.70 1.865 47.37 16 0.110 2.79 2.11 53.59 4513 6715 755 690 1005