    EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded 15KV, UL Type MV-105, 133% Ins. Level, 220 Mils

    Applications

    These cables are suitable for use in wet or dry locations when installed in accordance with NEC, use in aerial, conduit, open tray and underground duct installations and use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5). Besides, they are installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    Meets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method

    Optional Flame Tests:

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation colored to contrast with black conducting shield layers.

    Composite Insulation Shield and Jacket : Six corrugated copper drain wires embedded in composite layers of semi-conducting thermoset copolymer and semi-conducting black flame-retardant Chlorinated Polyethylene (CPE).

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Drain Wire Size Appr. Cable Diameter Appr. Cable Weight Appr. Copper Weight Ampacity
    AWG/kcmil Inches mm Min. Max. AWG Inches mm LBS/ 1000 FT kg/km LBS/ 1000 FT kg/km In Air GND.
    Inches mm Inches mm
    2 0.27 6.86 0.710 18.03 0.800 20.32 19 0.93 23.88 555 835 230 342 - 3
    1/0 0.34 8.89 0.780 19.81 0.865 21.97 18 1.01 25.91 734 1102 358 533 220 3.5
    2/0 0.38 9.65 0.820 20.83 0.905 22.99 18 1.05 27.18 844 1259 443 659 250 3.5
    3/0 0.43 10.92 0.865 21.97 0.955 24.26 18 1.10 28.45 978 1458 550 818 290 3.5
    4/0 0.48 12.19 0.920 23.37 1.005 25.53 18 1.16 29.72 1151 1716 685 1019 335 4
    250 0.53 13.46 0.970 24.64 1.060 26.93 17 1.23 31.50 1325 1984 813 1210 370 4
    350 0.62 15.75 1.070 27.18 1.155 29.34 17 1.33 33.78 1691 2530 1122 1669 460 5
    500 0.74 18.80 1.190 30.23 1.275 32.39 17 1.46 37.08 2238 3344 1585 2358 575 5
    750 0.91 23.11 1.370 34.80 1.460 37.08 16 1.67 42.42 3174 4739 2368 3523 745 6
    1000 1.06 26.92 1.520 38.61 1.610 40.89 16 1.86 47.24 4122 6133 3138 4669 890 6