    EPR/Copper Wire Shield/CPE, Medium-Voltage Power, Shielded 5KV and 8KV, UL Type MV-105, 133% / 100% Ins. Levels, 115 Mils

    Applications

    These cables are suitable for use in wet or dry locations when installed in accordance with NEC, use in aerial, conduit, open tray and underground duct installations and use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5). Besides, they are installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    Meets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method

    Optional Flame Tests :

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation colored to contrast with black conducting shield layers.

    Composite Insulation Shield and Jacket : Six corrugated copper drain wires embedded in composite layers of semi-conducting thermoset copolymer and semi-conducting black flame-retardant Chlorinated Polyethylene (CPE) .

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Inches Drain Wire Size Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. mm Max. mm AWG Inches mm LBS/1000 FT kg/km In Air GND.
    2 0.27 6.86 0.510 12.95 0.590 14.99 20 0.71 18.03 404 601 165 165
    1/0 0.34 8.64 0.580 14.73 0.655 16.64 20 0.78 19.81 555 825 215 215
    2/0 0.38 9.65 0.620 15.75 0.695 17.65 19 0.83 21.08 666 990 255 245
    3/0 0.43 10.92 0.665 16.89 0.745 18.92 19 0.88 22.35 791 1177 290 275
    4/0 0.48 12.19 0.720 18.29 0.795 20.19 19 0.93 23.62 951 1415 330 315
    250 0.53 13.46 0.770 19.56 0.850 21.59 18 1.01 25.65 1112 1655 365 345
    350 0.62 15.75 0.870 22.10 0.945 24.00 18 1.11 28.19 1463 2176 440 415
    500 0.74 18.80 0.990 25.15 1.065 27.05 17 1.24 31.50 2003 2980 535 500
    750 0.91 23.11 1.170 29.72 1.250 31.75 17 1.44 36.57 2875 4278 655 610
    1000 1.06 26.92 1.320 33.53 1.400 35.56 16 1.61 40.89 3746 5574 755 690