    EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 15KV, UL Type MV-105, 133% Ins. Level, 220 Mils

    Applications

    These cables are suitable for use in wet or dry locations when installed in accordance with NEC, use in aerial, conduit, open tray and underground duct installations and use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5). Besides, they are installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    Meets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method

    Optional Flame Tests :

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers.

    Extruded Insulation Shield (EIS) : Thermoset semi-conducting polymeric layer free stripping from insulation.

    Metallic Shield : 5 mil annealed copper tape with an overlap of 25%.

    Jacket : Flame-retardant Polyvinyl Chloride (PVC), UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Nominal Jacket Thickness Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. Max. Inches mm Inches mm LBS/ 1000 FT kg/km In Air GND. Tray
    Inches mm Inches mm
    2 0.27 6.86 0.710 18.03 0.800 20.32 0.080 2.03 0.99 25.14 658 979 165 165 -
    1 0.31 7.87 0.745 18.92 0.830 21.08 0.080 2.03 1.02 25.91 733 1090 190 185 -
    1/0 0.34 8.89 0.780 19.81 0.865 21.97 0.080 2.03 1.06 26.92 825 1228 215 215 220
    2/0 0.38 9.65 0.820 20.83 0.905 22.99 0.080 2.03 1.10 27.94 938 1396 255 245 250
    3/0 0.43 10.92 0.865 21.97 0.955 24.26 0.080 2.03 1.14 28.95 1078 1604 290 275 290
    4/0 0.48 12.19 0.920 23.37 1.005 25.53 0.080 2.03 1.21 30.73 1261 1876 330 315 335
    250 0.53 13.46 0.970 24.64 1.060 26.93 0.080 2.03 1.25 31.75 1407 2093 365 345 370
    350 0.62 15.75 1.070 27.18 1.155 29.34 0.080 2.03 1.35 34.29 1783 2653 440 415 460
    500 0.74 18.80 1.190 30.23 1.275 32.39 0.080 2.03 1.47 37.34 2331 3468 535 500 575
    750 0.91 23.11 1.370 34.80 1.460 37.08 0.080 2.03 1.65 41.91 3234 4812 655 610 745
    1000 1.06 26.92 1.520 38.61 1.610 40.89 0.110 2.79 1.86 47.24 4219 6278 755 690 890