    EPR/Copper Tape Shield with Overall CPE Jacket Medium-Voltage Power, Shielded, 5KV and 8KV, UL Type MV-105 133% / 100% Ins. Levels, 115 Mils, Three Conductor

    Applications

    These cables are suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical. Besides, they are installed in wet or dry locations accordance with NEC. Also in aerial, direct burial, conduit, open tray and underground duct installations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (70,000 BTU/hr)

    Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method

    Optional Flame Tests :

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers.

    Extruded Insulation Shield (EIS) : Thermoset semi-conducting polymeric layer free stripping from insulation.

    Metallic Shield : 5mil annealed copper tape with an overlap of 25%.

    Grounding Conductor : 1 bare grounding conductor may be in contact with metallic shielding tape.

    Overall Jacket : Flame-retardant Polyvinyl Chloride (CPE), UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Ground Wire Nominal Jacket Thickness Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. Max. AWG Inches mm Inches mm LBS/1000 FT kg/km In Air GND.
    Inches mm Inches mm
    6 0.17 4.32 0.415 10.54 0.490 12.45 6 0.080 2.03 1.29 32.77 939 1397 92 95
    4 0.22 5.39 0.455 11.56 0.535 13.59 6 0.080 2.03 1.39 35.31 1158 1723 120 125
    2 0.27 6.86 0.510 12.95 0.590 14.99 6 0.080 2.03 1.51 38.35 1511 2249 165 160
    1/0 0.34 8.89 0.580 14.73 0.655 16.64 4 0.080 2.03 1.67 42.42 2030 3021 215 210
    2/0 0.38 9.65 0.620 15.75 0.695 17.65 4 0.080 2.03 1.82 46.23 2449 3645 245 235
    4/0 0.48 12.19 0.720 18.29 0.795 20.19 3 0.110 2.79 2.07 52.58 3438 5116 320 305
    250 0.53 13.46 0.770 19.56 0.850 21.59 2 0.110 2.79 2.15 54.61 3968 5904 350 335
    350 0.62 15.75 0.870 22.10 0.945 24.00 2 0.110 2.79 2.36 59.94 5009 7454 430 400
    500 0.74 18.80 0.990 25.15 1.065 27.05 1 0.110 2.79 2.64 67.06 6793 10065 525 485
    750 0.91 23.11 1.170 29.72 1.250 31.75 1/0 0.140 3.56 3.14 79.76 9833 14633 635 585
    1000 1.06 26.92 1.330 33.78 1.400 35.56 2/0 0.140 3.56 3.48 88.39 12601 18753 725 660