    SOZ1-K(AS+)

    Application and Description

    These halogen-free cables are indicated for use in electric circuits for fire detection, alarms, pushbuttons, detectors, etc. Furthermore, this cable guarantees compliance with the applicable legislation, satisfying the fire resistance standard UNE-EN 50200, thus maintaining the operation of the installations when subject to fire, for 90 minutes at 400ºC, as established by the REBT in its ITC 28 "public premises". Subject to fire it does not emit acid or toxic gases so it guarantees the safety of people and of the installations.

    Standard and Approval

    UNE 211025

    IEC 60228

    IEC 60331-21

    IEC 60754

    IEC 60754-1

    UNE EN 50267-2-3

    UNE EN 50362 PH90

    UNE EN 61034-2

    UNE-EN 50200 PH90

    Cable Construction

    Flexible electrolytic copper conductor Class 5 according to UNE-EN 60228

    Silicone insulation type EI2 according to UNE-EN 50363

    Color coded to HD 308

    Polyester tape, tin plated copper drainage wire and polyester aluminum tape

    Halogen-free thermoplastic polyolefin sheath according to UNE 21123

    Technical Characteristics

    Working voltage 300/500 volts
    Test voltage 2000 volts
    Minimum bending radius 5 x Ø
    Working temperature -15°C to +90°C
    Short circuit temperature +250°C
    Insulation resistance 20 MΩ x km
    Halogen free UNE-EN 50267 and EN 50267
    No corrosive gases UNE-EN 50267 and EN 50267
    Low smoke density UNE-EN 61034, EN 61034 and IEC 61034
    Fire resistant UNE-EN 50200, EN 50200, UNE-EN 50362 and EN 50362
    Non-flame propagating IEC 60332-3, EN 50266-2
    Non-fire propagating according to UNE-EN 50266 and EN 50266

    Cable Parameter

    AWG No. of Cores × Nominal Cross Sectional Area Nominal Overall Diameter Nominal Weight
    # × mm² mm kg/km
    16(30/30) 2×1.5 8.6 105
    14(50/30) 2×2.5 9.9 135