SID-Silicone Single Core Solid Conductor Cable
Product application:
Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. Insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an insulation silicone dioxide layer will remain on the conductor to render it short circuit proof. Suitable for fixed installation.
Construction:
- Solid tinned copper single wire
- Solid to VDE-0295 Class-1, IEC 60228 Cl-1
- Silicone core insulation
Technical:
- Special silicone-insulated cable with higher heat-resistance adapted to DIN VDE 0250 part 1 and part 816
- Temperature range: -60°C to +180°C
- Short time temp up to +220º C
- Temperature limit at the conductor in operation +180°C
- Nominal voltage: 300/500 V
- Test voltage: 2000 V
- Insulation resistance :min. 200 MΩ x km
- Minimum bending radius: flexing 10 x cable Ø
- Coupling resistance :max. 250Ω/km
- Radiation resistance: up to 20x106 cJ/kg (up to 20 Mrad)
Properties
- Advantages
High ignition or flash point - Resistant to
High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lye and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen - Halogen-free
According to DIN VDE 0482 part 267/ EN 50267-2-1/ IEC 60754-1 (equivalent DIN VDE 0472 part 815) - Behavior in fire
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.
Product specification:
AWG | No. of Cores | Conductor Cross Section mm² | Nominal OD mm |
Copper weight kg / km |
Gross Weight kg / km |
---|---|---|---|---|---|
- | 1 | 0.2 | 1.7 | 1.9 | 4.2 |
- | 1 | 0.28 | 1.8 | 2.7 | 5.1 |
20 | 1 | 0.5 | 2 | 4.8 | 7.7 |
18 | 1 | 0.75 | 2.2 | 7.2 | 10.4 |
17 | 1 | 1 | 2.3 | 9.6 | 12.8 |
16 | 1 | 1.5 | 2.6 | 14.4 | 18 |
14 | 1 | 2.5 | 3.2 | 24 | 28.9 |
12 | 1 | 4 | 3.9 | 38 | 45.4 |
10 | 1 | 6 | 4.4 | 58 | 64.5 |
Other sizes and colours available on request