Fiber Optic Cables

    Application

This cable can provide excellent transmission performance and protection of fibers in a variety of fi eld environments. It is usually used in long haul communication system, subscriber network system, distribution, feeder network system and local area network system.

    Description

Central loose tube cable contains one tube with 12 fi ber ribbons, which is fi lled with water blocking gel. The fi ber ribbon can be easily separated by hand tool. Either aramid yarn or fi ber glass is wound around the tube to provide physical protection and tensile strength. The cable can be jacketed with either PE, PVC or LSZH though PE is the preferred option for water protection purpose. For direct burial, steel wire armour or corrugated steel tape armour is applied with an optional inner jacket of either PVC or PE. An optional Aluminium moisture tape can be incorporated under the jacket for water blocking and shielding purpose. An optional ripcord can be put under the jacket to facilitate jacket removal.

   Construction

Fiber Optic Cables
Fiber Optic Cables

    Physical Properties

Fiber Count

Nominal Weight(kg/km)

Nominal Weight(lb/kft)

Nominal Outer Diameter(mm)

Nominal Outer Diameter(in)

Maximum Pulling Load

Installation(N/Ib)

In Service(N/Ib)

12-96

166.0
111.41
16.2
0.637

2670/600

890/200

108-144

208.0
139.60
18.5
0.727

2670/600

890/200

156-216

244.0
163.76
20.5
0.806

2670/600

890/200

 Construction

   Physical Properties

Fiber Count

Nominal Weight(kg/km)

Nominal Weight(lb/kft)

Nominal Outer Diameter(mm)

Maximum Pulling Load

Installation(N/Ib)

In Service(N/Ib)

12-96
233.0
156.38
14.8

2670/600

890/200

108-144
276.0
185.23
16.1

2670/600

890/200

156-216
316.0
212.08
17.1

2670/600

890/200

   Mechanical Properties

Minimum Bending Radius:   Maximum Compressive Load: 3000N
Under installation: 20×OD Repeated Impact: 4.4 N.m (J)
During operation 10×OD for unarmoured cables Twist (Torsion): 180×10 times, 125×OD
  20×OD for armoured cables Cyclic Flexing: 25 cycles for armoured cables.
Temperature Range:     100 cycles for unarmoured cables.
Operating Temperature Range: -40℃(-40℉) to +70℃(+158℉) Crush Resistance: 263N/cm (150lb/in)
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉)    

   Fiber Compliance

Temperature Cycling
Tensile Strength
Crush
Impact
Repeated Bending
Torsion
Kink
Cable Bend
Cool Bend

IEC60794-1-2-F2
IEC60794-1-2-E1A
IEC60794-1-2-E3
IEC60794-1-2-E4
IEC60794-1-2-E6
IEC60794-1-2-E7
IEC60794-1-2-E10
IEC60794-1-2-E11
IEC60794-1-2-E11

   Safety Compliance

General Purpose Grade

Flammability Test: OFN (UL1581)

Riser Grade

Flammability Test: OFNR/FT4 (UL1666)

Plenum Grade

Flammability Test: OFNP/FT6 (UL 910)

FRPVC Grade

Flammability Test: IEC60332-1

LSZH Grade

Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2

LSFROH Grade 

Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2
Flammability Test: IEC60332-1 & IEC 60332-3C/A

FR Grade

Fire Resistance Test : IEC 60331 / BS 6387 CWZ

   Standard Compliance

        Telcordia GR-20          RUS 7 CFR 1755.900 (REA PE-90)                         ICEA S 87-640

   Features

• Large fi ber counts with small cable diameter
• Highly adaptable to mass splicing
• Suitable for installation in pipeline
• High quality jelly filled loose tube provides the ribbon fiber satisfactory mechanical and environmental protection.
• Ripcord allows easy jacket removal
• UV or moisture resistant for outdoor application
• Dry water blocking core design for ease of handling