    SR086 /M17

    Construction

    Inner conductor 

    Silver plated copper clad steel(SCCS) 

    Φ0.51 mm 

    Dielectric 

    PTFE 

    Φ1.67 ± 0.1mm 

    Outer conductor 

    type1:Seamless bare copper tube 

    Φ2.20 ± 0.1mm

    type2:Seamless copper tube, tin plated(TP) 

    type3:Seamless copper tube, silver plated(SP) 

    Electrical & Mechanical Characteristics

    Impedance 50±3 Ohm

    Nominal capacitance 

    95 pF/m 

    Velocity of propagation 

    -

    Insulation resistance 

    - Mohm.Km

    Inner conductor resistance 

    - Ohm/Km

    Outer conductor resistance 

    - Ohm/Km

    Operating temperature range 

    -55°C - +125 °C 

    Outer conductor integrity temperature 

    175°C 

    Min.bending radius 

    7.63 mm 

    Attenuation

    Frequency(MHz)  

    Max. Attenuation(dB/100m)  

    Max. Attenuation(dB/100ft)  

    500 45 13.7

    1000

    64

    19.5

    5000

    151

    46

    10000

    222

    67.7

    20000

    329

    100.3

     

     