Quick Contact
Inner conductor |
Corrugated copper tube |
Φ3.05 mm |
Dielectric |
Foam PE |
Φ8.64 mm |
Outer conductor |
Corrugated copper |
Φ9.65 mm |
Sheath |
PE/LSOH |
Φ11.18 mm |
Impedance |
50±3 Ohm |
Nominal capacitance |
76 pF/m |
Velocity of propagation |
88% |
Insulation resistance |
>5000 Mohm.Km |
Inner conductor resistance |
3.48 Ohm/Km |
Outer conductor resistance |
2.85 Ohm/Km |
Installation temperature range |
-40°C - +60 °C |
Operating temperature range |
-55°C - +85°C |
Test voltage |
4 KV |
Cable weight (approx.) |
120kg/km |
Operating Frequency Band |
1 – 13 GHz |
Screening effectiveness |
>120dB |
Frequency |
Attenuation |
Attenuation |
Frequency |
Attenuation |
Attenuation |
(MHz) |
(dB/100m) |
(dB/100ft) |
(MHz) |
(dB/100m) |
(dB/100ft) |
10 |
1.06 |
0.32 |
2000 |
16.97 |
5.17 |
100 |
3.42 |
1.04 |
2100 |
17.44 |
5.32 |
150 |
4.22 |
1.29 |
2200 |
17.91 |
5.46 |
200 |
4.9 |
1.49 |
2300 |
18.37 |
5.6 |
300 |
6.06 |
1.85 |
2500 |
19.26 |
5.87 |
450 |
7.51 |
2.29 |
2700 |
20.12 |
6.13 |
500 |
7.95 |
2.42 |
3000 |
21.38 |
6.52 |
700 |
9.52 |
2.9 |
4000 |
25.26 |
7.7 |
800 |
10.23 |
3.12 |
5000 |
28.81 |
8.78 |
900 |
10.87 |
3.31 |
6000 |
32.12 |
9.79 |
1000 |
11.55 |
3.52 |
8000 |
38.24 |
11.66 |
1500 |
14.45 |
4.41 |
8800 |
40.55 |
12.36 |
1700 |
15.49 |
4.72 |
10000 |
43.89 |
13.38 |
1800 |
15.99 |
4.88 |
12000 |
49.21 |
15 |
806-960 MHz |
23dB |
1700-2000 MHz |
23dB |