This FEP insulated multi-cores cable is used for automobiles.
Conductor : Cu-ETP1 or bare according to DIN EN 13602
Insulation : Fluorinated ethylene propylene(FEP) insulation
Sheath : Siliconne rubber,cross-linked according to ISO 14572 class F
Standard : ISO 6722 Class F
Operating temperature : –40°C to +210°C
Conductor Construction | Insulation | Cable | ||||||
---|---|---|---|---|---|---|---|---|
Nominal cross- section | No. and Dia. of Wires | Diameter max. | Electrical Resistance at 20°C Max. | Thickness Wall nom. | Sheath Thickness | Overall Diameter min. | Overall Diameter max. | Weight Approx. |
mm² | No./mm | mm | mΩ/m | mm | mm | mm | mm | kg/km |
2x0.35 | 12/0.21 | 0.8 | 52 | 0.4 | 0.53 | 4.6 | 5 | 32 |
2x0.25 | 24/0.16 | 0.7 | 86.5 | 0.4 | 0.53 | 3.4 | 3.8 | 24 |
*Note: Other configurations, sizes, colors and length not specified herein are available upon request.