Airport Cable  

   600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Single Core)

FGD300 1RVMV-R (CU/XLPE/PVC/AWA/PVC 600/1000V Class 2)

APPLICATION
The cables is mainly used in power stations, mass transit underground passenger systems,
airports, petrochemical plants, hotels, hospitals, and high-rise buildings.
STANDARDS
Basic design to BS 5467
FIRE PERFORMANCE

 

FlameRetardance (SingleVerticalWireTest)**

EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2);

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced FirePropagation(Vertically-mountedbundledwires

&cabletest)**

EN60332-3-24 (cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the
PVC compound and the cable design.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC 60228 class 2.
Insulation: Extruded cross-linked XLPE compound.
Inner sheath : PVC Compound
Armouring : Aluminium Wire
Outer Sheath : Thermoplastic PVC compound .

COLOUR CODE
Insulation Colour: Natural
Sheath Colour: Black (other colors upon request)
Physical AND THERMAL PROPERTIES
Temperature Range During Operation: -40°C ~ 70°C
Temperature Range during Installation : -5°C ~ 50°C
Minimum Bending Radius: 8 x OD
Electrical PROPERTIES

DielectricTest:

3500 Vr.m.s.x 5’(core/core)

Insulation Resistance

500 MΩ x km ( at 20°C )

ShortcircuitTemperature

250°C ( up to5secs)

CONSTRUCTION PARAMETERS

 

 

Cable
Code

Conductor

 

Diameter
Under
Armour

 

Armour Wire Diameter

 

Nominal
Overall Diameter

 

 

Approx. Weight

No. of CoreX

CrossSection

No./Nominal
Diameter
of
Strands

 

mm2

No./mm

mm

mm

mm

kg/km

FFGD3001RVMV-R 1G70

1x70

19/2.14

15.4

1.25

21.5

960

FFGD3001RVMV-R 1G95

1x95

19/2.52

17.3

1.25

23.4

1240

FFGD3001RVMV-R 1G120

1x120

37/2.03

19.1

1.6

25.9

1650

FFGD3001RVMV-R 1G150

1x150

37/2.25

21.1

1.6

27.9

1970

FFGD3001RVMV-R 1G185

1x185

37/2.52

23.2

1.6

30.1

2390

FFGD3001RVMV-R 1G240

1x240

61/2.25

26.2

1.6

33.2

3040

FFGD3001RVMV-R 1G300

1x300

61/2.52

28.8

1.6

35.8

3790

FFGD3001RVMV-R 1G400

1x400

61/2.85

32.7

2.0

40.9

4790

FFGD3001RVMV-R 1G500

1x500

61/3.20

36.2

2.0

44.6

5880

FFGD3001RVMV-R 1G630

1x630

127/2.52

40.6

2.0

49.2

7400

FFGD3001RVMV-R 1G800

1x800

127/2.85

45.7

2.5

55.7

9500

FFGD3001RVMV-R 1G1000

1x1000

127/3.20

50.6

2.5

61.0

11750

Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)

 Conductor
cross- sectional area

 Reference Method1(clipped

direct)

 Reference
Method11(ona
perforated

horizontalcabletrayor
Reference Method 13[freeair])

 Reference
Method 12(free air)

 Insingle-
wayducts

 Laiddirectin
ground

 

 

 

2

cables, single- phase

a.c.ord.c.

 

 

 

3 or 4cables, 3-phasea.c.

 

 

2

cables, single- phase

a.c.ord.c.

 

 

 

3 or 4cables, 3-phasea.c.

 

 

 

3cables 3-phase

a.c.trefoiltouching

 

 

2

cables, single- phase

a.c.ord.c.

 

 

 

3 or 4cables, 3-phasea.c.

 

 

2

cables, single- phase

a.c.ord.c.

 

 

 

3 or 4cables, 3-phasea.c.

1

2

3

4

5

6

7

8

9

10

mm2

A

A

A

A

A

A

A

A

A

70

303

277

322

293

285

310

280

340

290

95

367

333

389

352

346

365

330

405

345

120

425

383

449

405

402

410

370

460

389

150

488

437

516

462

463

445

405

510

435

185

557

496

587

524

529

485

440

580

490

240

656

579

689

612

625

550

500

670

560

300

755

662

792

700

720

610

550

750

630

400

853

717

899

767

815

640

580

830

700

500

962

791

1016

851

918

690

620

910

770

630

1082

861

1146

935

1027

750

670

1000

840

800

1170

904

1246

987

1119

828

735

1117

931

1000

1261

961

1345

1055

1214

919

811

1254

1038

Voltage Drop (Per Amp Per Meter)

 

 

Conductor cross-sectionalarea

 

 

 

2 cablesd.c.

 

2cables single-phasea.c.

 

3 or 4 cables three-phase a.c.

2 cables
single
phasea.c.

3 or 4 cables,3-phase a.c.touching

 

Reference Method 1

&

11 (touching)

Reference Method1,

11

& 12 (intrefoiltouching)

 

Reference Method 1

&11(Flattouching)

 

In ducts

 

In ground

 

In ducts

 

In ground

1

2

3

4

5

6

7

8

9

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

 

 

r

x

z

r

x

z

r

x

z

 

 

 

 

70

0.67

0.68

0.20

0.71

0.59

0.17

0.62

0.6

0.25

0.65

0.80

0.70

0.70

0.61

95

0.49

0.51

0.195

0.55

0.44

0.17

0.47

0.46

0.24

0.52

0.65

0.53

0.56

0.46

120

0.39

0.41

0.190

0.45

0.35

0.165

0.39

0.38

0.24

0.44

0.55

0.43

0.48

0.37

150

0.31

0.33

0.185

0.38

0.29

0.160

0.33

0.31

0.23

0.39

0.50

0.37

0.43

0.32

185

0.25

0.27

0.185

0.33

0.23

0.160

0.28

0.26

0.23

0.34

0.45

0.31

0.39

0.27

240

0.195

0.21

0.180

0.28

0.18

0.155

0.24

0.21

0.22

0.30

0.40

0.26

0.35

0.23

300

0.155

0.17

0.175

0.25

0.145

0.150

0.21

0.17

0.22

0.28

0.37

0.24

0.32

0.21

400

0.115

0.145

0.170

0.22

0.125

0.150

0.195

0.160

0.21

0.27

0.35

0.21

0.30

0.19

500

0.093

0.125

0.170

0.21

0.105

0.145

0.180

0.145

0.20

0.25

0.33

0.20

0.28

0.18

630

0.073

0.105

0.165

0.195

0.092

0.145

0.170

0.135

0.195

0.24

0.30

0.19

0.26

0.17

800

0.056

0.090

0.160

0.190

0.086

0.140

0.165

0.130

0.180

0.23

0.28

0.18

0.24

0.16

1000

0.045

0.092

0.155

0.180

0.080

0.135

0.155

0.125

0.170

0.21

0.26

0.17

0.22

0.15

Note :
r = conductor resistance at operating temperature
x = reactance
z = impedance