Airport Cable  

   300/500V PVC Insulated, PVC Sheathed Controlling Cables (1 Pair)

RE-YY (CU/PVC/PVC 300/500V Class 5)

APPLICATION
Indoor for: Intercom, Security, Sound, Audio, Background Music, and Power Limited Control
Circuits.
STANDARDS
Basic design adapted to BS 5308 and VDE 0812
FIRE PERFORMANCE

 

FlameRetardance (SingleVerticalWireTest)**

EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2);

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

 

Reduced FirePropagation(Vertically-mountedbundledwires

&cabletest)**

 

EN60332-3-24(cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
300/500V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to BS 6360 Class 5
Insulation: PVC insulation type TI1 to BS 7655
Outer Sheath: PVC sheath type T6 to BS 7655

COLOUR CODE
Insulation Color: Black , White
12AWG Jacket Color: Gray, Black
14AWG Jacket Color: Gray, Brown, Black, White
Electrical & Environmenta l Properties
Operating Temperature Range: -20˚C up to + 60˚C
12AWG Max.Capacitance Between Conductors @ 1 KHz: 109.55 pf/m Nom.
14AWG Max.Capacitance Between Conductors @ 1 KHz: 101.37 pf/m Nom.
Minimum Bending Radius: 6 x Overall Diameter
CONSTRUCTION PARAMETERS

Conductor

 

 

Nominal
Insulation Thickness

 

 

Nominal
Sheath Thickness

 

 

Nominal
Overall Diameter

 

 

Approx. Weight

Dc
Resistanceper conductor

@20℃

NO.of
PairsX

Cross Section

No./
Nominal
Diameterof
Strands

Conductor
Diameter

No.xAWG

No./mm

mm

mm

mm

mm

kg/km

Ω/km

1x2x12

53/0.31

1.95

0.6

0.8

9.4

145

4.95

1x2x14

41/0.254

1.55

0.6

0.8

8.6

91

8.3