Airport Cable  

   2491X to BS 6004 Cables

450/750V PVC Insulated, PVC Sheathed Electric Lock Cables (4 core)

FGD200 07VV-F (CU/PVC/PVC 450/750V Class 5)

APPLICATION
The cables are multicore stranded flexible cables sheathed with thermoplastic PVC compound. The
cables can be offered with the ability to restrict the propagation of the flame in the event of a fire. This
is especially important to slow down the spreading of the fire as the cables may pass from one area
to another within a building. Applications can be found in control and power circuits, power stations,
underground tunnels, lifts, escalators, and high-rise buildings.
STANDARDS
Basic design to BS 6004, BS6500
FIRE PERFORMANCE

FlameRetardance (SingleVerticalWireTest)**

EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2);

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced FirePropagation(Vertically-mountedbundledwires

&cabletest)**

EN60332-3-24 (cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
450/750V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to BS 6360 Class 5
Insulation: PVC insulation type TI1 to BS 7655
Filler, binder (if any): PP, PET
Outer Sheath: PVC sheath type T6 to BS 7655

COLOUR CODE
Insulation Colour as per BS7671

 

withearth conductor

withoutearth conductor

2Cores

-

Brown,Blue

3Cores

Yellow/Green,Brown,Blue

Brown,Gray,Black

4Cores

Yellow/Green,Brown,Gray,Black

Brown,Gray,Black,Blue

5Cores

Yellow/Green,Brown,Gray,Black,Blue

Brown,Gray,Black,Blue,Black

above 5 Cores

Yellow/Green,BlackNumbers

Black Numbers

Outer sheath: Black or as order
Physical AND THERMAL PROPERTIES
Operating temperature: -15º C to +70º C
Short circuit temperature: +160º C
Minimum bending radius: 4x Overall Diameter
Insulation resistance: 20 MΩxkm
CONSTRUCTION PARAMETERS

Conductor

fGD20007VV-f

No.of
CoreXCross
Section

No./
Nominal
Diameterof
Strands

Conductor
Diameter

Nominal
Insulation Thickness

Nominal
Sheath Thickness

Nominal
Overall Diameter

Max.DC resistance ofconductor

@20°C

Approx. Weight

Noxmm2

No./mm

mm

mm

mm

mm

Ω/km

kg/km

4x1.0

32/0.20

1.32

0.6

1.0

8.4

18.1

100

Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)

Conductor
cross- sectional area

Reference
Method4
(enclosed inconduit in thermally
insulating
walletc)

Reference
Method3 (enclosed inconduit ona wallorin

trunkingetc)

Reference
Method1(clipped direct)

Reference
Method11
(onaperforated cabletray,
horizontalo
rvertical)

Reference
Method 12
(freeair)

 

Horizontalflat spaced

 

Verticalflat spaced

 

 

Trefoil

2cables, single- phase
a.c.ord.c.

3 or 4cables, 3-phasea.c.

2
cables, single- phase
a.c.ord.c

3 or 4cables, 3-phasea.c.

2cables, single- phase
a.c.or
d.c. flat
andtouching

3 or 4cables, 3-phase
a.c. flat
andtouching or trefoil

2cables,
single-
phase
a.c.or
d.c.orflat and touching

3 or 4cables, 3-phase
a.c. flat
andtouching or trefoil

2cables,
single- phase
a.c.ord.c
.or 3cables
three

phase

2cables,
single- phase
a.c.ord.c.
or 3
cables three
phase

3 cables,
trefoil 3-phasea.c.

1

2

3

4

5

6

7

8

9

10

11

12

mm2

A

A

A

A

A

A

A

A

A

A

A

1.0

13

-

-

-

15

-

-

-

-

-

-

Voltage Drop (Per Amp Per Meter)

 

 

Nominal
Cross
Section Area

 

 

 

 

2cables d.c.

2cables,
single-phasea.c.

3or 4cables,3-phase a.c.

Ref.Methods3
and 4 (enclosedin
conduitetc,inoron a wall)

Ref.Methods1
and11
(clippeddirector ontray
stouching)

Ref.Methods3
and 4 (enclosedin
conduitetc,inoron a wall)

Ref.Methods1,

Ref.Methods
1and11

11 and12 (intrefoil)

 

(Flat and
touching)

1

2

3

4

5

6

7

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

1.0

46

46

-

-

-

-