Airport Cable | |||
2491X to BS 6004 Cables
450/750V PVC Insulated, Non-sheathed Cables (single core)
FGD100 07V-R (CU/PVC 450/750V Class 2)
APPLICATION
These cables are designed for use in the switch control, relay and instrumentation panels of power
switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and
controllers. The cables can be offered with the ability to restrict the propagation of the flame in the
event of a fire.
STANDARDS
Basic design to BS 6004
FIRE PERFORMANCE
Flame Retardance (SingleVerticalWireTest)** |
EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** |
EN60332-3-24 (cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBNC30-004(cat.F2);NFC32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
450/750V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Special PVC TI1 core insulation to BS 7655
COLOUR CODE
Insulation Colour: Brown, Black, Grey, Blue, Green/Yellow or as per order
Physical AND THERMAL PROPERTIES
Minimum bending radius: 6 x Overall Diameter
Flexing temperature: -5º C to +70º C
Static temperature: -30º C to +80º C
Short circuit temperature: +160º C
CONSTRUCTION PARAMETERS
Conductor |
FGD10007V-R |
|||
No.of Core XCross Section |
No./Nominal |
Nominal |
Nominal |
Approx.Weight |
Noxmm2 |
No./mm |
mm |
mm |
kg/km |
1x2.5 |
7/0.67 |
0.8 |
3.6 |
36 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor |
Reference insulating |
Reference trunkingetc) |
Reference |
Reference |
Reference |
||||||
Horizontal |
Vertical |
Trefoil |
|||||||||
|
2cables, single- phase |
3 or 4cables, 3-phasea.c. |
2cables, single- phase |
3 or 4cables, 3-phasea.c. |
2cables, single- phase a.c.or |
3 or 4cables, |
2cables,single- phase |
3 or 4cables, 3-phase |
2cables, single- |
2cables, single- phase |
3cables, trefoil 3- |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
mm2 |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
2.5 |
24 |
23 |
30 |
26 |
34 |
31 |
- |
- |
- |
- |
- |
Voltage Drop (Per Amp Per Meter)
Nominal |
2cables d.c. |
2 |
3 |
|||
Ref.Methods3 and 4(enclosed inconduitetc,inoron a wall) |
Ref.Methods1 |
Ref.Methods3 and 4(enclosed inconduitetc,inoron a wall) |
Ref. |
Ref.Methods |
||
11 and12 (intrefoil) |
(Flat and touching) |
|||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
mm2 |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
2.5 |
19 |
19 |
16 |
16 |
16 |
16 |