Airport Cable  

   600/1000V Mica+XLPE Insulated, LSZH Sheathed Power Cables

FFX300 1mRZ1-R (CU/MGT+XLPE/LSZH 600/1000V Single Core)

APPLICATION
This cable is designed for areas where the integrity of the electrical properties circuit is critical in
maintaining power supply. Applications can be found in emergency lightings, control and power
circuits, power stations, fire alarm systems, underground tunnels, communications systems,
sewage treatment plants, lifts, escalators, and high-rise buildings.
STANDARDS
Basic design to IEC 60502-1
FIRE PERFORMANCE

 

Circuit Integrity

IEC60331-21;BS6387 CWZ;DINVDE0472-814(FE180);

CEI20-36/2-1; SS229-1;NBNC30-004 (cat.F3);NF C32-070-2.3(CR1)

SystemCircuitIntegrity

DIN4102-12, E30depending on lay system

 

Flame Retardance (SingleVerticalWireTest)

EN60332-1-2; IEC60332-1-2; BSEN60332-1-2;VDE0482-332-1 ; NBNC30-004 (cat.F1);

NF C32-070-2.1(C2); CEI 20-35/1-2; EN50265-2-1*;DIN VDE 0482-265-2-1*

Reduced FirePropagation(Vertically-mountedbundledwires

&cabletest)

EN60332-3-24 (cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBNC30-004(cat.F2);NFC32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;CEI20-37/2-1;BS6425-1*

NoCorrosive GasEmission

IEC60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;CEI20-37/2-2;BS6425-2*

MinimumSmokeEmission

IEC61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;CEI20-37/3-1&2; EN50268-1&2*;BS 7622-1&2*

NoToxic Gases

NES02-713;NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING
600/1000 V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC 60228 class 2
Insulation: Mica glass tape covered by extruded cross-linked XLPE compound
Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1
COLOUR CODE
Insulation Colour: Natural
Sheath Colour: Black (other colors upon request)
Physical AND THERMAL PROPERTIES
Temperature Range During Operation: -30°C ~ 90°C
Temperature Range during Installation : -5°C ~ 50°C
Minimum Bending Radius: 6 x OD
Electrical PROPERTIES

DielectricTest:

3500 Vr.m.s.x 5’(core/core)

Insulation Resistance

1000 MΩ x km ( at 20°C )

ShortcircuitTemperature

250°C ( up to5secs)

CONSTRUCTION PARAMETERS

 

 

Cale
Code

Conductor

 

Approx. Overall Diameter

 

 

Approx. Weight

Nominal
CrossSection Area

No./

Nominal
Diameter
of
Strands

 

Dia.of
Conductor

 

Nominal
Insulation Thickness

 

mm2

No./mm

mm

mm

mm

kg/km

FFX300 1mRZ1-R1G1.5

1.5

7/0.53

1.59

0.7

6.5

54

FFX300 1mRZ1-R1G2.5

2.5

7/0.67

2.01

0.7

6.8

67

FFX300 1mRZ1-R1G4

4

7/0.85

2.55

0.7

7.5

86

FFX300 1mRZ1-R1G6

6

7/1.04

3.12

0.7

8.1

110

FFX300 1mRZ1-R1G10

10

7/1.35

4.05

0.7

9.2

155

FFX300 1mRZ1-R1G16

16

7/1.70

5.1

0.7

10.2

220

FFX300 1mRZ1-R1G25

25

7/2.14

6.42

0.9

11.9

325

FFX300 1mRZ1-R1G35

35

19/1.53

7.65

0.9

13.2

425

FFX300 1mRZ1-R1G50

50

19/1.78

8.9

1

14.6

600

FFX300 1mRZ1-R1G70

70

19/2.14

10.7

1.1

16.6

820

FFX300 1mRZ1-R1G92

95

19/2.52

12.6

1.1

18.7

1100

FFX300 1mRZ1-R1G120

120

37/2.03

14.21

1.2

20.5

1350

FFX300 1mRZ1-R1G150

150

37/2.25

15.75

1.4

22.7

1640

FFX300 1mRZ1-R1G185

185

37/2.52

17.64

1.6

25.5

2040

FFX300 1mRZ1-R1G240

240

61/2.25

20.25

1.7

28.5

2650

FFX300 1mRZ1-R1G300

300

61/2.52

22.68

1.8

31.5

3260

FFX300 1mRZ1-R1G400

400

65/2.85

25.65

2

35.4

4130

FFX300 1mRZ1-R1G500

500

61/3.20

28.8

2.2

39

5200

FFX300 1mRZ1-R1G630

630

127/2.52

32.76

2.4

43.5

6600

FFX300 1mRZ1-R1G800

800

127/2.85

37.05

2.6

48.5

8300

FFX300 1mRZ1-R1G1000

1000

127/3.20

41.6

2.8

53.5

10000

ElectricAl PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)

 

Conductor
cross- section area

Reference
Method4
(enclosed inconduitin thermally

insulating
walletc)

Reference
Method3
(enclosed inconduiton a wallorin trunkingetc)

 

 

Reference
Method1
(clipped direct)

 

Reference
Method11
(onaperforated
cabletray,
horizon
talorvertical)

 

Reference
Method 12
(free air)

 Horizontal

flat spaced

 Vertical flat
spaced

 Trefoil

2cables, single- phase

a.c.ord.c.

 3 or 4cables, 3-phasea.c.

2cables, single- phase

a.c.ord.c

 3 or 4cables, 3-phasea.c.

2cables, single- phasea
.c.ord.c.

flat and

touching

3 or 4cables, 3-phase

a.c. flat
and
touching or trefoil

2cables,
single- phasea.c.ord.c. orflat and touching

3 or 4
cables, 3-phase
a.c. flat
and
touching or trefoil

2cables,
single- phasea.c.
ord.c. or3
cables
three
phase

2cables, single- phasea.c.
or d.c. or 3cables
three phase

 

3cables, trefoil

3-phasea.c.

1

2

3

4

5

6

7

8

9

10

11

12

mm2

A

A

A

A

A

A

A

A

A

A

A

1.5

18

17

22

19

25

23

-

-

-

-

-

2.5

24

23

30

26

34

31

-

-

-

-

-

4

33

30

40

35

46

41

-

-

-

-

-

6

43

39

51

45

59

54

-

-

-

-

-

10

58

53

71

63

81

74

-

-

-

-

-

16

76

70

95

85

109

99

-

-

-

-

-

25

100

91

126

111

143

130

158

140

183

163

138

35

125

111

156

138

176

161

195

176

226

203

171

50

149

135

189

168

228

209

293

215

274

246

209

70

189

170

240

214

293

268

308

279

351

318

270

95

228

205

290

259

355

326

375

341

426

389

330

120

263

235

336

299

413

379

436

398

495

453

385

150

300

270

375

328

476

436

505

461

570

524

445

185

341

306

426

370

545

500

579

530

651

600

511

240

400

358

500

433

644

590

686

630

769

711

606

300

459

410

573

493

743

681

794

730

886

824

701

400

-

-

684

584

868

793

915

849

1065

994

820

500

-

-

783

666

990

904

1044

973

1228

1150

936

630

-

-

900

764

1130

1033

1191

1115

1423

1338

1069

800

-

-

-

-

1288

1179

1358

1275

1580

1485

1214

1000

-

-

-

-

1443

1323

1520

1436

1775

1671

1349

Voltage Drop (Per Amp Per Meter)

 

 

Nominal
CrossSection Area

 

 

 

2cablesd.c.

2cables,
single-phasea.c.

3or 4cables, 3-phase a.c.

 

Ref.
Methods3 and 4(enclosed inconduitetc
,inoron a wall)

 

Ref.
Methods1

and11(clipped
directoron traystouching)

 

Ref.
Methods3 and 4(enclosed inconduitetc,
inoron a wall)

 

Ref.
Methods1,

 

Ref.
Methods1and11

11 and12 (intrefoil)

 

(Flat and touching)

1

2

3

4

5

6

7

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

1.5

31

31

27

27

27

27

2.5

19

19

16

16

16

16

4

33

12

10

10

10

10

6

7.8

7.9

6.8

6.8

6.8

6.8

10

4.7

4.7

4.7

4

4

4

16

2.9

2.9

2.9

2.5

2.5

2.5

 

 

r

x

z

r

x

z

r

x

z

r

x

z

r

x

z

25

1.85

1.85

0.31

1.9

1.85

0.19

1.85

1.6

0.27

1.65

1.6

0.165

1.6

1.6

0.19

1.6

35

1.35

1.35

0.29

1.35

1.35

0.18

1.35

1.15

0.25

1.15

1.15

0.155

1.5

1.15

0.18

1.15

50

0.99

1

0.29

1.05

0.99

0.18

1

0.87

0.25

0.9

0.86

0.155

0.87

0.86

0.18

0.87

70

0.68

0.7

0.28

0.75

0.68

0.175

0.71

0.6

0.24

0.65

0.59

0.15

0.61

0.59

0.175

0.62

95

0.49

0.51

0.27

0.58

0.49

0.17

0.52

0.44

0.23

0.5

0.43

0.145

0.45

0.43

0.17

0.46

120

0.39

0.41

0.26

0.48

0.39

0.165

0.43

0.35

0.23

0.42

0.34

0.14

0.37

0.34

0.165

0.38

150

0.32

0.33

0.26

0.43

0.32

0.165

0.36

0.29

0.23

0.37

0.28

0.14

0.31

0.28

0.165

0.32

185

0.25

0.27

0.26

0.37

0.26

0.165

0.3

0.23

0.23

0.32

0.22

0.14

0.26

0.22

0.165

0.28

240

0.19

0.21

0.26

0.33

0.2

0.16

0.25

0.185

0.22

0.29

0.17

0.14

0.22

0.17

0.165

0.24

300

0.155

0.175

0.25

0.31

0.16

0.16

0.22

0.15

0.22

0.27

0.14

0.14

0.195

0.135

0.16

0.21

400

0.12

0.14

0.25

0.29

0.13

0.155

0.2

0.125

0.22

0.25

0.11

0.135

0.175

0.11

0.16

0.195

500

0.093

0.12

0.25

0.28

0.105

0.155

0.185

0.1

0.22

0.24

0.09

0.135

0.16

0.088

0.16

0.18

630

0.072

0.1

0.25

0.27

0.086

0.155

0.175

0.088

0.21

0.23

0.074

0.135

0.15

0.071

0.16

0.17

800

0.056

-

-

-

0.072

0.15

0.17

-

-

-

0.062

0.13

0.145

0.059

0.155

0.165

1000

0.045

-

-

-

0.063

0.15

0.165

-

-

-

0.055

0.13

0.14

0.05

0.155

0.165

Note: r = conductor resistance at operating temperature
x = reactance
z = impedance