Telephone Cables | |||||||||||
A-02YSOF(L)2Y n x 2 Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1
Reference Standard: A-02Y(L)2Y Outdoor Telecommunication Cable according to DIN VDE 0816 Part 1
Application: This cable is used in local telephone networks as subscriber cable
Conductor Material: Solid annealed copper conductor
Insulation Material: Foamed PE (02YS)
Laying-up: Star quads in unit stranding
Wrapping: Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20℃ to +50 ℃ fixed installation: - 40℃ to + 70℃
Operating Voltage: 225V
Electrical Performance:
Conductor Diameter (mm) |
Insulation Resistance of per km at 20 o C Min. (GOhms) |
Conductor Resistance per km loop Max. (Ohms) |
0.60 |
5 |
130 |
0.80 |
5 |
73.2 |
Size & Dimensions:
A - 02YSOF(L)2Y ... x 2 x 0.8 STIII BD
Part No. |
No.of pairs |
Outer diameter |
Cable Weight |
Copper Weight |
CCL-TC-02YSOF6P0.8 |
6 |
11.5 |
150 |
60 |
CCL-TC-02YSOF10P08 |
10 |
13.0 |
210 |
101 |
CCL-TC-02YSOF20P0.8 |
20 |
16.5 |
360 |
201 |
CCL-TC-02YSOF30P0.8 |
30 |
19.0 |
500 |
302 |
CCL-TC-02YSOF40P0.8 |
40 |
21.0 |
640 |
402 |
CCL-TC-02YSOF50P0.8 |
50 |
23.0 |
775 |
503 |
CCL-TC-02YSOF70P0.8 |
70 |
27.0 |
1060 |
704 |
CCL-TC-02YSOF100P0.8 |
100 |
31.0 |
1455 |
1005 |
CCL-TC-02YSOF150P0.8 |
150 |
38.0 |
2155 |
1508 |