Mining Cable  
 

Mining Cable

         Type W Four-Conductor Flat Portable Power Cable 2kV

Applications

These cables are designed for general use where baregrounding conductors are not required ordesired.

Standards

Construction

Type W Four-Conductor Flat Portable Power Cable 2kV

Options:

Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

Dimensions and Weight:

Construction No. of Strands Nominal Insulation Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil   inch mm inch mm lbs/kft kg/km A
8 166 0.06 1.5 0.83 21.1 391 581 72
6 259 0.06 1.5 0.94 23.9 571 849 95
4 412 0.06 1.5 1.07 27.3 793 1180 127
2 259 0.06 1.5 1.26 32.1 1142 1699 167
1/0 414 0.08 2.0 1.51 38.3 1693 2520 217
2/0 522 0.08 2.0 1.65 41.9 1908 2840 250
3/0 658 0.08 2.0 1.77 45.0 2600 3870 286
4/0 829 0.08 2.0 1.92 48.8 2675 3980 328
250 973 0.095 2.4 2.10 53.3 3434 5110 363

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.