Data Cable |
|||
Screened Signal Pair Cable
Application:
General purpose foil screened single pair cables with a small outer diameter, frequently used in audio, data, and instrumentation applications. Polyethylene insulation results in lower signal loss than the standard PVC insulation.
Construction:
Tinned copper conductor, polyethylene insulation, colours black & clear (black & white in LSHF) , twisted pair, aluminium/polyester foil screen, tinned copper drain wire, PVC sheath on standard cable. LDPE on Duct grade. UL Style 2092, 300V, 60°C. Sizes 16 & 14 AWG are 600V, 80°C.
Technical Data:
Belden No. |
No. of Pairs |
AWG |
CSA mm² |
Weight Kg/Km |
O/D mm |
Capacitance C/C |
pF/m C/Smm |
8451 | 1 | 22(7) | 0.35 | 20 | 3.4 | 111 | 220 |
LSHF | 1 | 22(7) | 0.35 | 20 | 3.5 | 111 | 220 |
8761 | 1 | 22(7) | 0.35 | 25 | 4.6 | 79 | 154 |
LSHF | 1 | 22(7) | 0.35 | 25 | 4.6 | 79 | 154 |
DUCT | 1 | 22(7) | 0.35 | 27 | 6.2 | 79 | 154 |
8762 | 1 | 20(7) | 0.56 | 35 | 5.1 | 89 | 161 |
LSHF | 1 | 20(7) | 0.56 | 35 | 5.1 | 89 | 161 |
DUCT | 1 | 20(7) | 0.56 | 38 | 6.5 | 89 | 161 |
8760 | 1 | 18(16) | 0.79 | 45 | 6.0 | 79 | 144 |
LSHF | 1 | 18(16) | 0.79 | 45 | 6.0 | 79 | 144 |
DUCT | 1 | 18(16) | 0.79 | 48 | 7.6 | 79 | 144 |
8719 | 1 | 16(19) | 1.34 | 84 | 7.9 | 75 | 144 |
LSHF | 1 | 16(19) | 1.34 | 84 | 7.9 | 75 | 144 |
8720 | 1 | 14(19) | 1.92 | 109 | 9.0 | 79 | 154 |
LSHF | 1 | 14(19) | 1.92 | 109 | 9.0 | 79 | 154 |