Robotics

Robotics

Extra Flex H3-H4 PVC-PVC

Type

Code

Formation

Ext.Diam mm

CU-weight kg/km

H3

H3BH8RDC

3x(2x0.14)+2x0.50

8.8(+/-0.3)

68

H4

H4BK8RDC

3x(2x0.14)+2x1

9.4(+/-0.3)

79

APPLICATION :
Data Transmission, Connection for Heidenhain measuring systems, Dynamic Applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
250V
Test Voltage :
1500V
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Capacitance :
abt. 195 pF/m at 20oC (cond./cond.)
Temperature :
service from 0oC to +80oC, storage from -30oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
special PVC compound
Conductors Identification :
pairs 0.14mm2: YE-GRN - PK-GRY - RD-BL cond. 0.5/1mm2: WHT -BR
EMC Shield :
tinned copper braid covering >/= 85% on pairs: tinned copper spiral coverage 100%
Taping :
special tape
Jacket :
special PVC compound black colour RAL 9005 or grey RAL 7001
Min. Bending Radius :
100mm
Translation Speed :
120m/min.
Max. Acceleration :
4m/s2
Reference Standards :
VDE 0472-804 C - IEC 332-3A - CEI 20-22 II for flame resistance VDE 0472-803-B for ASTM2 oil resistance CNOMO E.03.40.150N - NFT 46-013 for resistance to industrial oils UL - CSA upon rsequest
.