Railway Cables | ||||||||||||
K13 PVC Subway Signalling Cables for
Metro/Local Trains/Tramlines
Application
The cables are designed for remote control and teletransmission in underground railway networks. The cables can be laid in channel, cable tray, or on hook supports, along suburban railway lines electrifi ed at maximum 1500V DC
Standards
● AFNOR NF F 55-633
Construction
Conductors
Solid copper conductor, 0.6/0.8/1.0/1.2 mm nominal diameter.
Insulation
Polyethylene insulation.
Cabling Element
Pair/Quad.
Stranding
4-pair cables are composed of pairs, while other cables are composed of star quads.
Spare Pairs
Spare pairs may be provided according to capacity of cables.
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap.
Screen
Aluminium/Nylon tape bonded with a special PVC sealing sheath or Aluminium/PE tape bonded with a
halogen-free fi re-retardant sheath.
Drain Wire
A tinned copper drain wire, 0.5mm nominal diameter.
Bedding
Several glass silk tapes are helically laid with an overlap to form bedding.
Armour
Two helically applied steel tapes.
Outer Sheath
LSPVC.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm |
0.6 |
0.8 |
1.0 |
1.2 |
Nominal Mutual Capacity | nF/km |
57.5 |
57.5 |
57.5 |
57.5 |
Minimum Insulation Resistance | MΩ.km |
5000 |
5000 |
5000 |
5000 |
Maximum Operating Voltage | V |
200 |
400 |
500 |
750 |
Maximum Permissible Current | A |
0.35 |
0.63 |
1.0 |
1.4 |
Mechanical and Thermal Properties
Minimum Bending Radius: 8×OD (static); 16×OD (dynamic)
Temperature Range: -40℃ to +60℃ (during operation); -20℃ to +50℃ (during installation)
Core Identification
4-pair cable:
Pair1: black/colourless Pair2: blue/ colourless
Pair3: yellow/colourless Pair4: red/ colourless
Other cable:
Side circuit 1 of a quad a-wire: sequence of black/blue/yellow/red/green/blue/yellow, etc.
b-wire: colourless
Side circuit 2 of a quad a-wire: grey
b-wire: white
Unit binder: sequence of white/blue/yellow/brown/black/red/green/violet
Dimensions And Weight
Cable Code |
Number of Pairs |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
Inner |
Outer |
||||
0.6mm Conductor, 0.96mm Insulated Wire |
|||||
RS/K13-2Y(L)2YBY-4P0.6 |
4 |
1.0 |
1.0 |
12.5 |
220 |
RS/K13-2Y(L)2YBY-8P0.6 |
8(4Q) |
1.0 |
1.0 |
13.5 |
260 |
RS/K13-2Y(L)2YBY-14P0.6 |
14(7Q) |
1.0 |
1.2 |
15.5 |
350 |
RS/K13-2Y(L)2YBY-28P0.6 |
28(14Q) |
1.0 |
1.4 |
17.5 |
480 |
RS/K13-2Y(L)2YBY-56P0.6 |
56(4 x 7Q) |
1.0 |
1.4 |
22.0 |
750 |
0.8mm Conductor, 1.27mm Insulated Wire |
|||||
RS/K13-2Y(L)2YBY-4P0.8 |
4 |
1.0 |
1.0 |
14.0 |
280 |
RS/K13-2Y(L)2YBY-8P0.8 |
8(4Q) |
1.0 |
1.2 |
15.0 |
340 |
RS/K13-2Y(L)2YBY-14P0.8 |
14(7Q) |
1.0 |
1.4 |
18.0 |
470 |
RS/K13-2Y(L)2YBY-28P0.8 |
28(14Q) |
1.0 |
1.4 |
21.0 |
700 |
RS/K13-2Y(L)2YBY-56P0.8 |
56(4 x 7Q) |
1.0 |
1.6 |
28.5 |
1200 |
1.0mm Conductor, 1.8mm Insulated Wire |
|||||
RS/K13-2Y(L)2YBY-4P1 |
4 |
1.0 |
1.2 |
15.5 |
340 |
RS/K13-2Y(L)2YBY-8P1 |
8(4Q) |
1.0 |
1.4 |
17.5 |
460 |
RS/K13-2Y(L)2YBY-14P1 |
14(7Q) |
1.0 |
1.4 |
20.5 |
630 |
RS/K13-2Y(L)2YBY-28P1 |
28(14Q) |
1.0 |
1.6 |
25.0 |
990 |
RS/K13-2Y(L)2YBY-56P1 |
56(4 x 7Q) |
1.0 |
1.8 |
34.0 |
1700 |
1.2mm Conductor, 2.0mm Insulated Wire |
|||||
RS/K13-2Y(L)2YBY-2P1.2 |
2(1Q) |
1.0 |
1.2 |
12.5 |
240 |
RS/K13-2Y(L)2YBY-4P1.2 |
4 |
1.0 |
1.4 |
17.0 |
420 |
RS/K13-2Y(L)2YBY-8P1.2 |
8(4Q) |
1.0 |
1.4 |
18.5 |
530 |
RS/K13-2Y(L)2YBY-14P1.2 |
14(7Q) |
1.0 |
1.4 |
21.5 |
740 |
RS/K13-2Y(L)2YBY-28P1.2 |
28(14Q) |
1.0 |
1.6 |
27.5 |
1250 |