IEC60092 STANDARD Offshore & Marine Cables 
MariFlex Marine Fire Resistant Power & Control Cables

MariSig Fire Resistant Instrumentation & Control Cables

MRE-M2XH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation & Control Cables (Multicore)

MRE-M2XH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation & Control Cables (Multicore)

Application
These cables are used on board of ships in all locations for fixed installations not subject to mechanical risk complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.

Standards
 IEC 60092-350/351/376/359
 IEC 60331-21
 IEC 60332-1
 IEC 60332-3-22
 IEC 60754-1/2
 IEC 61034

Construction
 Conductors: Class 2 stranded copper conductor.
 Insulation: Mica tape + XLPE.
 Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.

Core Identification
White with printed number.

Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 4×OD
Temperature Range: -30℃ ~ +80℃

Dimensions and Weight

Part No.

Construction
No. of cores×Cross
section(mm²)

Nominal Insulation Thickness
mm

Nominal Sheath Thickness mm

Nominal Overall
Diameter mm

Nominal Weight kg/km

MRE-M2XH-2C0.75

2×0.75

0.5

1.1

6.3

63

MRE-M2XH-4C0.75

4×0.75

0.5

1.2

6.7

84