IEC60092 STANDARD Offshore & Marine Cables |
|
|
MariSig Fire Resistant Instrumentation & Control Cables
MRE-M2XH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1)
Sheathed Fire Resistant Instrumentation & Control Cables
(Multicore)
Application
These cables are used on board of ships in all locations for fixed installations not subject
to mechanical risk complying with IEC standards 60092-352 in safety circuit, where fire
resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen
free, suitable for installations on passenger ships, as on other commercial vessels.
Standards
IEC 60092-350/351/376/359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction
Conductors: Class 2 stranded copper conductor.
Insulation: Mica tape + XLPE.
Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.
Core Identification
White with printed number.
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 4×OD
Temperature Range: -30℃ ~ +80℃
Dimensions and Weight
Part No. |
Construction
No. of cores×Cross
section(mm²) |
Nominal Insulation Thickness
mm |
Nominal Sheath Thickness mm |
Nominal Overall
Diameter mm |
Nominal Weight kg/km |
MRE-M2XH-2C0.75 |
2×0.75 |
0.5 |
1.1 |
6.3 |
63 |
MRE-M2XH-4C0.75 |
4×0.75 |
0.5 |
1.2 |
6.7 |
84 |
|