Marine Cable  

Marine Cable

P3 or P3/P10 RFOU/TFOU 6/10KV

Applications :

  • These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards :

  • IEC 60092-353 IEC 60092-351
    IEC 60092-359 IEC 60332-1
    IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
 

Construction :

  • Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
  • Conductor Screen : Semi conducting material.
  • Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
  • Insulation Screen : Semi conducting material and tinned copper wire braid.
  • Bedding : Halogen free compound.
  • Armour : Tinned copper wire braid.
  • Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.

Electrical Characteristics :

  • Nominal Cross Section Area mm² 16 25 35 50 70 95 120
    Nominal Conductor Diameter mm 5.2 6.5 7.4 8.7 10.3 12.2 13.8
    Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154
    Continuous Current Rating@45℃1 Core A 96 127 157 196 242 293 339
    Continuous Current Rating@45℃3 Core A 67 89 110 137 169 205 237
    Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590 17170
    Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
    Nominal Cross Section Area mm² 150 185 240 300 400 500 630
    Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3
    Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286
    Continuous Current Rating@45℃1 Core A 389 444 522 601 690 780 890
    Continuous Current Rating@45℃3 Core A 272 311 365 421 483 546 623
    Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140
    Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Ambient Temperature Correction Factors :

  • Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80
    Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties :

  • Bending Radius :15×OD (during installation); 9×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
1×16 3.4 1.5 1.1 24.0 900
1×25 3.4 1.5 1.2 26.0 1140
1×35 3.4 1.6 1.2 26.9 1265
1×50 3.4 1.6 1.2 28.3 1460
1×70 3.4 1.7 1.3 30.0 1710
1×95 3.4 1.8 1.3 32.0 2060
1×120 3.4 1.8 1.4 33.8 2380
1×150 3.4 1.9 1.4 35.3 2700
1×185 3.4 2.0 1.5 37.8 3225
1×240 3.4 2.1 1.6 41.0 3990
1×300 3.4 2.2 1.6 43.7 4760
1×400 3.4 2.3 1.7 45.5 5900
1×500 3.4 2.4 1.8 49.5 7350
1×630 3.4 2.6 1.9 54.5 8750
3×16 3.4 2.3 1.7 46.0 3300
3×25 3.4 2.4 1.8 50.1 3905
3×35 3.4 2.5 1.8 52.2 4360
3×50 3.4 2.6 1.9 55.1 5185
3×70 3.4 2.7 2.0 58.9 6125
3×95 3.4 2.9 2.1 63.5 7500
3×120 3.4 3.0 2.2 67.6 8775
3×150 3.4 3.2 2.3 71.7 10235
3×185 3.4 3.4 2.4 74.0 11300
3×240 3.4 3.6 2.6 79.5 13300
3×300 3.4 3.8 2.7 85.0 16300