Coaxial Cables

Tri-RG393

 

Construction

Inner conductor 

Silver plated copper 

7 x 0.80 mm 

Dielectric 

Solid PTFE 

Φ7.25 ± 0.10 mm 

Outer conductor (shield 1) 

Silver plated copper (0.16mm) 

Φ7.95 ± 0.10 mm 

Inner sheath 

FEP 

Φ9.00 ± 0.10 mm 

Outer conductor (shield 2) 

Silver plated copper (0.2mm) 

Φ9.90 ± 0.10 mm 

Outer sheath 

FEP 

Φ11.10 ± 0.10 mm 

Electrical & Mechanical Characteristics

Impedance 

50±3 Ohm

Nominal capacitance 

94 pF/m 

Velocity of propagation 

70%

Insulation resistance 

- Mohm.Km

Inner conductor resistance 

- Ohm/Km 

Outer conductor resistance 

- Ohm/Km 

Operatig Voltage(max) 

4.4 KV 

Test Voltage 

Operating temperature range 

-55°C - +200 °C 

Cable weight (approx.) 

290 Kg/Km 

Screening effectiveness 

>60 dB 

Attenuation

Frequency (MHz)  

Attenuation (dB/100 m)  

Max. Attenuation(dB/100ft)  

100 7 2.1

200

10

3

400

14

4.3

900

22

6.7

1200

25

7.6

1500

29

8.8

1800

32

9.8

2000

34

10.4

2500

39

11.9