Coaxial Cables

M17/29-RG 59 (RG 59 B/U)

Construction

Inner conductor 

Copper clad steel(CCS) 

Φ0.58 ± 0.03 mm 

Dielectric 

Low density PE 

Φ3.70 ± 0.10 mm 

Outer conductor (shield) 

Plain copper 

120 x 0.15 mm 

Shield coverage 

95%

Sheath 

PVC or LSZH 

Φ6.20 ± 0.10 mm 

Electrical & Mechanical Characteristics

Impedance 

75±5 Ohm 

Nominal capacitance 

67 pF/m 

Velocity of propagation 

66%

Insulation resistance 

>2000 Mohm.Km 

Inner conductor resistance 

158 Ohm/Km 

Outer conductor resistance 

9.0 Ohm/Km 

Test/Operatig Voltage(max) 

5.0 KV/3.5 KV 

Operating temperature range

 -30 °C - +70 °C 

Copper weight 

22.4 Kg/Km 

Cable weight (approx.) 

55.8 Kg/Km 

Screening effectiveness 

>55 dB 

Attenuation

Frequency(MHz) 50 

Attenuation (dB/100 m) 7.4 

Attenuation (dB/100ft) 2.26 

100

10.7

3.26

200

15.7

4.79

400

22.7

6.92

500

25.7

7.84

600

28.7

8.75

860

34.8

10.61

1000

38

11.59

Return Loss

30-300 MHz 

>31dB

300-600 MHz 

>28dB

600-900 MHz 

>24dB