Coaxial Cables

M17/112-RG304 (RG 304/U)

Construction

Inner conductor 

Silver plated copper covered steel 

Φ1.50 mm 

Dielectric 

Solid PTFE 

Φ4.75 mm 

Outer conductor(shield 1) 

Silver plated copper 

144 x 0.16 

Shield coverage 

95%

Outer conductor(shield 2) 

Silver plated copper 

144 x 0.16 

Shield coverage 

95%

Sheath 

FEP 

Φ7.10 mm 

Electrical & Mechanical Characteristics

Impedance 

50±3 Ohm 

Nominal capacitance 

96.5 pF/m

Velocity of propagation 

70%

Insulation resistance 

>2000 Mohm.Km 

Inner conductor resistance 

36.2 Ohm/Km 

Outer conductor resistance 

4.3 Ohm/Km 

Test/Operatig Voltage(max) 

5.0 KV/3.0 KV 

Operating temperature range 

-55 °C - +200 °C 

Copper Weight 

- KG/Km

Cable weight (approx.) 

130 Kg/Km 

Screening effectiveness 

80 dB 

Attenuation

Frequency (MHz) 

Attenuation (dB/100 m) 

Attenuation (dB/100ft) 

50

5.6

1.71

100

8.5

2.59

200

13.5

4.12

400

18

5.49

700

24.9

7.59

900

27.9

8.51

1000

30.2

9.21

3000

56.8

17.32

5000

77.1

23.51

8000

114.8

35

Return Loss

30-300 MHz 

>31dB

300-600 MHz 

>27dB

600-900 MHz 

>24dB