Coaxial Cables | ||||||||||||
M17/84-RG 223 (RG 223/U)
Construction
Inner conductor |
Silver plated copper |
Φ0.90 ± 0.025 mm |
Dielectric |
Low density PE |
Φ2.95 ± 0.10 mm |
Outer conductor(shield 1) |
Silver plated copper |
112 x 0.13 mm |
Shield coverage |
|
98% |
Outer conductor(shield 2) |
Silver plated copper |
112 x 0.13 mm |
Shield coverage |
|
97% |
Sheath |
PVC or LSZH |
Φ5.40 ± 0.10 mm |
Electrical & Mechanical Characteristics
Impedance | 50±3 Ohm0 | |
Nominal capacitance | 100pF/m | |
Velocity of propagation | 66% | |
Insulation resistance | >2000 Mohm.Km | |
Inner conductor resistance | 28 Ohm/Km | |
Outer conductor resistance |
8.0 Ohm/Km |
|
Test/Operatig Voltage(max) |
5.0KV/2.0KV |
|
Operating temperature range |
-30 °C - +70 °C |
|
Copper Weight |
38.5 Kg/Km |
|
Cable weight (approx.) |
59.9 Kg/Km |
|
Screening effectiveness |
100-900 MHz |
>70dB |
Attenuation
Frequency(MHz) |
Attenuation (dB/100 m) |
Attenuation (dB/100ft) |
50 |
9 |
2.74 |
100 |
13 |
3.96 |
200 |
19.3 |
5.88 |
400 |
28.1 |
8.57 |
500 |
31.9 |
9.73 |
600 |
35.3 |
10.76 |
860 |
43.8 |
13.35 |
1000 |
48.5 |
14.79 |
3000 |
83.2 |
25.37 |
5000 |
109.9 |
33.51 |
11000 |
177.5 |
54.12 |
Return Loss
30-300 MHz |
>32dB |
300-600 MHz |
>28dB |
600-900 MHz |
>23dB |