Coaxial Cables

LCX12(1/2″) L

Coaxial Cables

Construction

Inner conductor 

Coppe clad Aluminium or copper

 Φ4.8 mm 

Dielectric 

Foam PE 

Φ12.3 mm 

Outer conductor 

Corrugated copper tube and slot 

Φ13.8 mm 

Sheath 

PE/LSOH 

Φ15.7 mm 

Electrical & Mechanical Characteristics

Impedance 

50±3 Ohm 

Nominal capacitance 

76 pF/m 

Velocity of propagation 

88%

Insulation resistance 

>5000 Mohm.Km 

Inner conductor resistance 

1.48 Ohm/Km 

Outer conductor resistance 

2.10 Ohm/Km 

Installation temperature range 

-40°C - +60 °C 

Operating temperature range 

-55°C - +85°C 

Cable weight (approx.) 

230kg/km/260kg/km 

Attenuation

Frequency(MHz) 

Attenuation (dB/100 m)  

Attenuation (dB/100 ft) 

75

2

0.61

150

2.9

0.88

450

5.3

1.62

800

7.3

2.23

900

7.9

2.41

1800

12

3.66

2200

13.5

4.12

2400

14.1

4.3