Coaxial Cables | ||||||||||||||
RG Coax
RG223 |
|||
Product Name/Code : RG223 |
Electrical Performance |
||
Application : |
Electrical Characteristics: |
||
For communication and signal control systems. |
Frequency |
Attenuation |
|
Reference Standard |
(MHz) |
(dB/100m) |
|
Customer's sample spec. and the general standard |
50 |
6.1 |
|
100 |
12.0 |
||
Cable Construction |
200 |
21.6 |
|
Center Conductor |
Silver Plated Copper |
400 |
30.5 |
Dia. |
1/0.91 |
700 |
33.7 |
Insulation |
Solid PE |
900 |
44.5 |
Nom. Thickness(mm) |
1.0 |
1000 |
46.8 |
Insulation Dia. (±0.03mm) |
2.95 |
Operating Temperature( ? ) |
80 |
Bonded Al Foil +Silver Plated Copper Braid Shield 1 |
Capacitance(pF/m) |
100 |
|
Construction |
16/ 6/0.12 |
Velocity ratio (+/-5%) |
66.6 |
Coverage Area(%) |
>=75 |
Impedance(+/-3 Ω ) |
50 |
Bonded Al Foil +Silver Plated Copper Braid Shield 2 |
|||
Construction |
6/ 7/0.12 |
||
Coverage Area(%) |
>=90 |
||
Jacket |
PVC |
||
Nom. Thickness(mm) |
1.05 |
||
Cable Dia.(±0.10mm) |
5.3 |
|
|
Jacket Compound |
PVC/LSF/LSOH |
|
|
Core Identification/Color Code |
According to customer request |
|
|
Bending Radius |
6 x Overall Diameter |
|
|
Temperature Rating |
70 ℃ |
|
|
Voltage Rating |
300/500V |
|
|
Fire Performance |
|
|
|
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH ) Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH ) Smoke Density Test to IEC 61034 ( LSOH ) Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH ) Temperature Index Test to BS 2782 or ISO 4589-3 ( LSOH ) |
|||
Website: www.caledonian-cables.com | |||
E-mail: sales@caledonian-cables.com |