CCL- 8125
Product Name/Code: 8125 Electrical Performance
Application: Max. inner Conductor Resistance £¨¦¸/Km£© 85
Multi-Conductor-Audio, Control, & Instrumentation Cables Voltage Rating(V) 30
Construction Nominal Impedance( ¦¸ )
100
25Pairs Stranded Tinned Copper Nominal Velocity ratio (%) 78%
AWG 24 Capacitance (pF/m) C1 42
Construction 7x0.20 Capacitance (pF/m) C2 73
Conductor Diameter (mm) 0.54    
Insulation PVC/PE/PP/XLPE/LSF/LSOH    
Thickness 0.40    
Insulation Diameter(mm) 1.34    
Insulation Color

White/Blue&Blue/White, White/Orange&Orange/White

   

White/Green&Green/White,White/Brown&Brown/White

White/Gray&Gray/White, Red/Blue&Blue/white

Red/Orange&Orange/White, Red/Green&Green/Red

Red/Brown&Brown/Red, Red/Gray&Gray/Red

Black/Blue&Blue/Black, Black/Orange&Orange/Black

Black/Green&Green/Black, Black/Brown&Brown/Black

Black/Gray&Gray/Black, Yellow/Blue&Blue/Yellow

Yellow/Orange&Orange/Yellow, Yellow/Green&Green/Yellow

Yellow/Brown&Brown, Yellow/Gray&Gray/Yellow

Purple/Blue&Blue/Purple, Purple/Orange&Orange/Purple

Purple/Green&Green&Purple, Purple/Brown&Brown/Purple

Purple/Gray&Gray/Purple

Individual Screen Aluminum Foil-Polyester Tape    
Coverage 100%    
   
Overall Screen Tinned Copper Braiding    
Coverage 65%    
Construction Multi pair individually shielded with overall screen laid up in tinned copper braid    
Sheath PVC/LSF/LSOH    
Thickness(mm) 1.2    
Diameter(mm)
16.8
   
Core Identification/Color Code
According to customer request
   
Bending Radius 6xOverall Diameter    
Operating Temperature( ¡æ ) -30/80    
Fire Performance
   
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperature Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24
   