CCL-9519 |
|||
Product Name/Code: 9519 | Electrical Performance |
||
Application: | Max. inner Conductor Resistance £¨¦¸/Km£© | 85 | |
Multi-Conductor-Audio, Control, & Instrumentation Cables | Voltage Rating(V) | 300 | |
Construction | Nominal Impedance ( ¦¸ ) | 75 | |
19 PAIRS(38 CORES) | Stranded Tinned Copper | Nominal Velocity ratio (%) | 60% |
AWG | 24 | Capacitance (pF/m) C1 | 94 |
Construction | 7x0.20 | Capacitance (pF/m) C2 | 160 |
Conductor Diameter (mm) | 0.54 | ||
Insulation | PVC/PE/PP/XLPE/LSF/LSOH | ||
Thickness | 0.40 | ||
Insulation Diameter(mm) | 1.34 | ||
Insulation Color | Black &Red,Black&White,Black&Green,Black&Blue, Black&Yellow,Black&Orange,Red&White,Red&Green, Red&Blue.Red&Yellow,Red&Brown,Red&Orange, Red&White,Green&White,Green&Blue,Green& Red, Green&Blue,White&Blue |
||
Drain wire | Stranded Tinned Copper | ||
AWG | 24 | ||
Construction | 7x0.20 | ||
Over all Screen | AL/PET | ||
Construction | Multipair overall laid up in aluminum-Foil Polyester Tape Screen | ||
Sheath | PVC/LSF/LSOH | ||
Thickness(mm) | 0.8 | ||
Diameter(mm) | 11.5 | ||
Core Identification/Color Code | According to customer request | ||
Bending Radius | 6xOverall Diameter | ||
Operating Temperature( ¡æ ) | -30/80 | ||
Fire Performance |
|||
Flame Propagation Test to IEC 60332 Part 1 and Part 3 Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 Smoke Density Test to IEC 61034 Oxygen Index Test to BS 2863 or ISO 4589-2 Temperature Index Test to BS 2782 or ISO 4589-3 Fire Resistant Test to IEC 60331-24 |
|||
website: www.caledonian-cables.com email: sales@caledonian-cables.com |
|||