SPEAKER 2C 16AWG
Product Name/Code :SPEAKER 2C 16AWG Electrical Performance
Application :
Multi-conductor-audio/sound, control.& Instrumentation Cables. Operating Temperature(¡æ) 75
Construction Voltage Rating(V) 300/500
2 Core Oxygen Free Copper wire strands  
AWG 16
Cross section of Cons. Diameter (mm2) 1.29
Stranding(wire No./ wire dia.mm) 26/0.25mm    
Insulation PVC
Thickness (mm) 0.21
Insulation Diameter(mm) 1.62
Insulation Color According to customer
Nylon rip cord 150D
Sheathing PVC/PE/LSOH  
Thickness(mm) 0.7  
Cable Dia.(mm) 4.7  
Fire Performance
Fire Performance
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperatre Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24

website: www.caledonian-cables.com

email: sales@caledonian-cables.com