SECURITY 3C 16AWG
Product Name/Code :SECURITY 3C 16AWG Electrical Performance
Application :
Power limited circuit, remote control, signaling, security systems, communications, intercom/P.A. systems, sound/audio, and nurse call. Operating Temperature(¡æ) 75
Construction Voltage Rating(V) 300/500
3 Core Bare copper wire strands  
AWG 16
Cross section of Cons. Diameter (mm2) 1.31
Stranding(wire No./ wire dia.mm) 42/0.20mm
Insulation PE/PVC
Thickness (mm) 0.38
Insulation Diameter(mm) 1.90
Insulation Color According to customer
Nylon rip cord 150D
Drain Wire Solid bare copper
Construction 24AWG
Shield (Y/N) Overall Al/Polyester foil shield
Coverage > 25%
Sheathing PVC/PE/LSF  
Thickness(mm) 0.8  
Cable Dia.(mm) 6.5  
Fire Performance
Fire Performance
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperatre Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24