RG213

Product Name/Code : RG213

Electrical Performance

Application :

Electrical Characteristics:

For communication and signal control systems.

Frequency

Attenuation

Reference Standard

(MHz)

(dB/100m)

Customer's sample spec. and the general standard

50

4.1

100

9.8

Cable Construction

200

16.5

Center Conductor

Bare Copper

400

19.8

Dia.

7/0.75

700

22.1

Insulation

Solid PE

900

24.7

Nom. Thickness(mm)

2.45

1000

26.6

Insulation Dia. (±0.03mm)

7.25

Operating Temperature( ? )

80

Bare Copper Braid Shield

Capacitance(pF/m)

100

Construction

16/ 10/0.18

Velocity ratio (+/-5%)

66

Coverage Area(%)

>=95

 Impedance(+/-3 Ω )

50

Jacket

PVC

Nom. Thickness(mm)

1.35

Cable Dia.(±0.10mm)

10.3

 

 

Jacket Compound

PVC/LSF/LSOH

 

 

Core Identification/Color Code

According to customer request

 

 

Bending Radius

6 x Overall Diameter

 

 

Temperature Rating

70 ℃

 

 

Voltage Rating

300/500V

 

 

Fire Performance

 

 

 

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH )

Website: www.caledonian-cables.com

 

 

E-mail: sales@caledonian-cables.com