CCL-CT 125PE

Product Name/Code : CCL-CT125PE

Electrical Performance

Application :

Max. Conductor DC Resistance at 20 ¡æ ( ¦¸ /Km ) 8 9.00

15.2

For communication and signal control systems.

Min. Insulation DC Resistance at 20 ¡æ ( M ¦¸ *Km )

>500

Reference Standard

Operating Temperature( ¡æ )

70

Customer's sample spec. and the general standard

Voltage Rating(V)

1500

Cable Construction

Capacitance(+/-3pF/m)

55

Center Conductor

Bare Copper

Velocity ratio ( +/- 5 %)

80

Diameter(mm)

1 /1.25

Impedance(+/-3 ¦¸ )

75

Insulation

Cellular PE

Attenuation at 20 ¡æ (-dB/100m)

Nom Thickness(mm)

2.17

50MHz

3.4

Insulation Diameter (¡À0.03mm)

5.60

100MHz

5.9

CU/Polyester tape

100%

200MHz

7.0

Braid Shield

Bare Copper Braid

400MHz

11.1

Construction

16/4/0.14

700MHz

 13.0

Coverage Area(%)

>=54

900MHz

15.8

Sheathing

PE

1000MHz

 16.5

Min. Thickness(mm)

1.05

 

 

Diameter(¡À0.10mm)

7.80

 

 

Sheathing Compound

PVC/LSF/LSOH

 

 

Core Identification/Color Code

According to customer request

 

 

Bending Radius

6xOverall Diameter

 

 

Temperature Rating

70 ¡æ

 

 

Voltage Rating

300/500V

 

 

Fire Performance

 

 

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH )

 

 

Website: www.caledonian-cables.com

 

E-mail:sales@caledonian-cables.com